5
4
TROUBLE SHOOT
Check power whether or not is provided.
Check the fuse whether or not is broken.
Check wire connection
Always call qualified engineer for maintenance to avoid dangers.
Always unplug the power supply first before disassemble the screen.
If your motorized screen is with switch control, please refer the fig
below for electric connection.
If your motorized screen is with remote control, please refer the fig
below for electric connection.
SPECIAL FUNCTION: TO SET UP THE REMOTE CONTROLLER
Important Attention: Press button continuously, each operation must
be within 10 seconds.
Upper and lower limit switch is in the right end of the screen
housing. Refer the fig below to adjust the upper limit and the lower
limit. For the safety reason, never disassemble the limit switch.
ADJUSTING YELLOE LEVER
LIMIT SWITCH
LIMIT
SWITCH
LOWER POSITION
UPPER POSITION
SWITCH
SWITCH
TUBULAR MOTOR
BROWN
BLUE
YELLOW/GREEN
TUBULAR MOTOR
L1
G
L2
230VAC
M
SCREEN REMOTE CONTROLLER
UP
N
DOWN
CONNECT THE LINE PILLAR
BLACK
BROWN
BLUE
BLACK
PLUG
SWITCH CASE
L1
PLUG
FUSE
BROWN
BROWN
BROWN
BROWN
BLACK
BLACK
BLACK
BLUE
BLUE
YELLOW/GREEN
TUBULAR MOTOR
M
UP
N
DOWN
CINNECT THE LINE PILLAR
G
L2
MAIN SWITCH
230VAC
SWITCH CASE
L
PLUG
FUSE
BLACK
RED
RED
BLACK
BLACK
WHITE
YELLOW
WHITE
BLACK
TUBULAR MOTOR
M
UP
N
DOWN
CINNECT THE LINE PILLAR
G
N
MAIN SWITCH
120V AC/60Hz
The limit time of tubular motor is 5 minutes without stop.It will turn on
the overhead switch after long time using(until it becomes cool
completely)
If remote control does not work well, please check the battery and
replace new one.
RED
WHITE
YELLOW
TUBULAR MOTOR
L
G
N
120V AC/60Hz
SCREEN REMOTE CONTROLLER
UP
N
DOWN
TERMINAL BLOCK
BLACK
RED
WHITE
BLACK
BLACK
YELLOW
WHITE
PLUG
M
Summary of Contents for 81214