20
6.7.3 Listening-in connection
Possible
tone-dialling commands
during the
listening-in connection
DTMF
=> Every valid command will be signalled
0
Terminate
phone connection
and acknowledge alarm
1
Switching to hands-free mode and restart
connection time-out
2
Repeat announcements (
Individual message
/ Cause of alarm)
3
Restart
connection time-out
(2 minutes)
4
Deactivate output (i.e. switching
off
230VAC load)
5
Announcement of current supervision mode as well as condition of the output
6
Activate output (i.e. switching
on
230VAC load)
7
Change to
inactive supervision mode
(I, II, III)
8
Terminate
phone connection
without acknowledgment
9
Change to
active supervision mode
(I, II, III) => All monitoring functions re-activated
* * 0
Announcement of calling number sequence
* *
n
Announcement of calling number
n
(
n
= 1..9)
Following
tone-dialling command
can be used for remote programming, provided the programming is not
blocked (
section 9.8.1)
* * #
Trigger an alarm for test reasons
Cause of alarm announcement "alarm due to programming"
* *
n
* followed by the new calling number
Announcement and change of calling number
n
(
n
= 1..9)
* * # #
Record individual message => according to section 5.3.1.
6.7.4 Hands-free connection
The commands during
hands-free connection
are identical to the commands by listening in connection, by press
DTMF 1 .
Important notes:
Hands-free connection
must be terminated using DTMF 0 or 8 . Otherwise a busy tone signal
appears until
phone connection
is terminated due to time-out.
By selecting
hands-free connection
an activated siren (optionally) is automatically deactivated. If
requested, the siren can be activated or deactivated by DTMF 6 or 4 .
6.7.4.1 Adjustment of hands-free volume
During
hands-free connection
you can increase volume by pressing local key
#
.
or decrease by pressing locale
key
*
.
. Level can be adjusted in fifteen steps (1dB each) and remains stored.
6.7.5 Acknowledge alarm / Terminate connection
A called party can choose between acknowledgment by pressing DTMF 0 or passing on alarm to next party
in calling number sequence by pressing DTMF 8 .
Important notes:
There is no alarm repetition, if an alarm is triggered by pressing any key of the alarm unit (test call).
An alarm can be confirmed and terminated by pressing key
0
.
of the alarm unit or by pressing the
wireless emergency button for a second time.
If the alarm is programmed to a pager, the called person can confirm alarm during remote-access
after dialling-in.
6.8 Alarm repetition
If an alarm has not been acknowledged by passing all the calling numbers in the sequence, a number of alarm
repetitions can be programmed (
section 9.2). Factory setting: two alarm repetitions.
6.9 Test call
If alarm unit is switched to ON it is possible to start a test call as follows:
1. Select calling number by pressing key
<n>
(
n
=
1
.
..
9
)
Announcement: „Calling number
<n>
“ => If selected calling number is not programmed the
message “Error” will be announced and the first calling number will be dialled instead
2. Wait until
hands-free connection
is established and speak
3. Terminate
phone connection
by pressing
0
.
or slide
function switch
to OFF
Notes:
After two minutes
phone connection
will automatically terminate if called party does not give any
tone-
dialling commands
(i.e. called subscriber can disconnect using DTMF 0 or restart timer using DTMF 3 ).
During
inactive waiting period
after power on key
9
.
and
7
.
activate or deactivate the monitoring of the
supervision. Key
5
.
starts the announcement of the current supervision mode (
section 6.3.1)
The volume of
hands-free connection
can be adjusted as described in section 6.7.4.1