17
6. OPERATION
6.1 Self check at power on
After power on the alarm unit checks battery, mains power supply and telephone-line conditions. If one of these
tests fails an appropriate message will be announced (battery error/power failure/line-check error).
Three beep: Mains power loss AND battery low at the same time!
Quickly handle the announce problem, otherwise the alarm functions are not guarantied.
6.1.1 Auto-detection of wired sensor
EasyAlarm
detects the connected motion sensor automatically during the switching on procedure (factory
setting) and corresponding supervision will be activated.
Important notes:
By disconnecting the motion detector during operation, an alarm is triggered with the
announcement: „Alarm due to sensor 1, sensor failure”!
By connecting the motion detector during operation, an alarm is triggered with the announcement:
„Alarm due to sensor 1”!
6.2 Arm / Disarm system
After power on
automatically arms the system. During operation
can be
armed/disarmed using the remote control or during any telephone connection using DTMF 7 and 9 .
Announce “supervision activated “ or “supervision deactivated”
6.2.1 Announcement of open contact sensors
If the system is set to arm all open wireless contacts expect the ones with entry/exit functionality will be
announced:
Announcement: “zone x,y,z, is open”
After the exit period remaining wireless contacts will be announced. These zones will be auto by-passed
(monitoring temporary disabled). If one of these zones returns to the closed position, the by-pass will be
removed and the system starts to monitor the corresponding zone.
Note:
The state of the contact (open/close) after power-up can be selected according to section 9.11.2. The default
value is: all contacts are open! The state of any contact zone will than be auto-synchronised after the first
transmission (opening/closing or status report every 65min)
6.3 Exit delay (inactive waiting period when the system change to armed state)
The system remains inactive for 20 seconds after power on, after arming or changing the
position of selection switch.
If you press a key of the alarm unit the following reactions will occur:
Key
Action
5
Announcement of the monitored functions
(
Exit delay
period will be restarted)
7
Immediately
changes to disarmed state
9
Immediately
changes to armed state and the
exit delay
period starts again.
Others
Test-call
(
section 6.9) will be made to the first calling number
Notes:
The entry/exit period 20 seconds can be adjusted according to section 9.3
If there are unacknowledged alarms, their number and the reason of the last alarm will be announced.
Battery low of a wireless sensor will be announced: “Battery fault, Zone n”
Missing status reports of a wireless sensor will be announced: “Sensor fault, Zone n”
6.3.1 Announcement of the monitored functions
The monitored functions corresponding to the position of the
selection switch
will be announced:
"Supervision I/II/III <deactivated>" followed by enabled (activated) monitoring functions:
Wireless zones with sensor function 0..7
Announcement:
"due to zone n"
Acoustical monitoring
Announcement:
"due to noise"
Sensor-1-monitoring
Announcement:
"due to sensor 1 activated”
Sensor-2-monitoring
Announcement:
"due to sensor 2 activated”
Notes:
Zones with sensor function panic/emergency (type 7+8) and telecommand (type 9+0) will NOT be
announced.
If at power up the output is active, the corresponding announcement will be made.