27
9. SPECIAL PROGRAMMING
Important notes:
All parameters remain stored even if
is switched off or without battery. Therefore
reprogramming is only essential if parameters have to be changed.
Programming mode can be locked to secure against unintended programming during operation (
section 5.4.1). If lock is activated, the announcement „programming inactive: PIN“ will be
announced if
function switch
is shifted to PROG.
Attention: Changing these parameters below does influence the operating mode. Therefore only
necessary parameters should be changed. Please test behaviour before putting the unit back into
operation!
A programming error can be corrected by repeating the programming steps accordingly.
9.1 Factory settings (Default-Values)
can be reset to default values as follows:
OFF
ON
PROG
Keep
3
and
#
pressed
simultaneously
OFF
ON
PROG
Release
keys
OFF
ON
PROG
9.2 Alarm repetition
An alarm is triggered, as soon as the alarm criteria is fulfilled and the
waiting period
has expired. In some cases
it might be useful to repeat an alarm as long until an acknowledgement is received.
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
5 3
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
0
calls the alarm numbers within the calling number sequence just once
1..9
starts calling the calling numbers within the calling number sequence until the alarm is
confirmed by DTMF 0 or until the programmed value is reached!
(factory setting =2)
9.3 Entry/Exit delay
The appropriated register
4 8
can be read-out or modified as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
4 8
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
0..255
Time in seconds
(factory setting=20)
9.4 Mains power loss timeout
The appropriated register
6 3
can be read-out or modified as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
6 3
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Value
Comment
1..255
Period for mains power loss, before a alarm is activated : in 10 minute steps ! (deviation:-10/+0min)
(factory setting=2,
i.e.. alarm is triggered if the mains voltage precipitates during 10..20min).
9.5 Signalling
9.5.1 Signalling through alarm unit
It is possible to signal the inactive waiting period with one beep every two seconds. Proceed as follows:
OFF
ON
PROG
*
.
9
.
7
.
1
.
3
0 5
#
.
#
.
*
.
Value
#
.
OFF
ON
PROG
Signalling..
Value
Mains loss
at power-on
Selected mode
after power-on
Exit
Beep every 2 sec.
Entry
: 2 Beep
0
1
2
3
4
Value
Value
Value
Value
Prog. 2