ADA-6081 User Manual
13
Installation and Setup
Chapter 2: Installation
Audio Peak Level Detect Settings
The factory setting of the audio peak level detect is +8 dBu.
The peak audio level thresholds may be adjusted as follows:
Audio Silence Detect Level Settings
The factory setting of the audio silence detect is -36 dBu. The silence
level thresholds may be adjusted as follows:
GPI Output Configuration
Two GPI Outputs are provided via the 15-way connector on the A10 and
AV12 rear connector modules for all
four audio channels. GPO1 reports
errors detected on channels 1 and 2 and GPO2 reports errors detected
on channels 3 and 4. The position of the jumper link on CN14 defines
the nature of the third GPO connection, GPO_GLO:
Channel
Minimum Threshold
(+3 dBu)
Maximum Threshold
(+18 dBu)
1
VR 7 fully clockwise
VR 7 fully counter-clockwise
2
VR 9 fully clockwise
VR 9 fully counter-clockwise
3
VR 3 fully clockwise
VR 3 fully counter-clockwise
4
VR 1 fully clockwise
VR 1 fully counter-clockwise
Channel
Max. Threshold
Min. Threshold
1
VR 6 fully clockwise
VR 6 fully counter-clockwise
2
VR 8 fully clockwise
VR 8 fully counter-clockwise
3
VR 4 fully clockwise
VR 4 fully counter-clockwise
4
VR 2 fully clockwise
VR 2 fully counter-clockwise
CN14
Pins A and B Linked Pins B and C Linked
Function
+5 V output (normal)
Global GPI output connection
Summary of Contents for ADA-6081
Page 1: ...175 000040 00 Edition B User Manual Analog Audio Distribution Amplifier ADA 6081 ...
Page 5: ...ADA 6081 Analog Audio Distribution Amplifier User Manual Edition B July 2002 ...
Page 6: ......
Page 20: ...Preface xvi ADA 6081 User Manual ...
Page 22: ...Contents xviii ADA 6081 User Manual ...
Page 36: ...Chapter 2 Installation Installation and Setup 14 ADA 6081 User Manual ...
Page 42: ......