background image

SYMPTOMS

FAULT

REMEDY

1. Pilot will not light

automatically.

No spark across electrode gap. (a) Ensure that pizeo-electric

igniter is functioning

correctly.

(b) Check that electrical lead

is not damaged. 

2. Pilot will not light

automatically but points (a)
to (e) are satisfactory and
the pilot will light with a
match. 

Incorrect position of spark in
relation to pilot gas flow.

Re-position spark plug so that
spark jumps across gas flow.

3. Heater will not remain alight

when pressure is released
from ignition button. 

Electro-magnetic valve closes
whilst heater is alight. 

(c) Ensure that thermocouple

probe is located in pilot
flame.

(d) Ensure good connection

between thermocouple
and valve.

(e) Check thermocouple.
(f)  Check electromagnetic

valve.(by gas engineer). 

4. After changing to maximum

position with all three
plaques alight. One or more
plaques appear below
normal intensity. 

(a) Blocked jets.
(b) Partially blocked supply

tube.

(a) Remove and clean blocked

jet.

(b) Remove supply tube,

remove jets and blow
through the tube. 

5. Difficulty in cross lighting

from position 1 to position
2 or 3. 

(a) Air draught directed away

from first plaque.

(b) Position of the pilot flame. 

(a) Change the location of the

appliance so that it is not
adversely affected by air
draught.

(b) Position pilot so that flame

impinges across bottom
corner of 2nd plaque as
well as 1st plaque. 

6. Smell of combustion. 

Missing piece of ceramic
fireclay. 

Inspect perimeter of each
plaque and locate place 
where some fireclay has
been displaced. Check with
qualified engineer.

FAULT FINDLING CHART

(REPAIR TO BE CONDUCTED BY AUTHORISED PRESONNEL ONLY)

Summary of Contents for LW638

Page 1: ...Portable Butane Cabinet Heater LW638 Red LW639 Black Read and understand these instructions before attempting any operation of this heater and retain for future reference ...

Page 2: ...ed linens and other flammable materials may ignite if placed against the outlets of your heater 16 In the event of a leak the appliance valve should be turned off and the regulator disconnected from the container 17 After use turn off the appliance at the gas valve 18 Only use in a well ventilated area STORAGE 1 Disconnect container 2 Store container in a well ventilated area away from combustible...

Page 3: ...1 Ignition Button 2 Control Button 3 Carrying handles 4 Guard 5 Atmospheric sensing device pilot with flame supervision device and ignition system 1 2 3 5 4 ...

Page 4: ...om the empty container 6 Following the steps described in Connecting the gas tank to connect a filled one IMPORTANT 1 It is important that all gas connections have been correctly connected to prevent any leakage 2 Put gas tank in an upright position Using the gas tank horizontally may damage your heater and create serious problems 3 If a newly fitted gas tank is used ignition may be impaired as th...

Page 5: ...tion m If pilot flame goes out please repeat procedure 3 HEAT LEVEL SETTINGS To change from minimum to medium Please gently press down the control button and turn it to position mm To change from medium to maximum Please gently press down the control button and turn it to position mmm 4 SWITCHING OFF Please gently press down the control button and turn to position I Turn off the gas supply on the ...

Page 6: ...airs fabrics bed linen and other furniture 4 DO NOT move Heater from room to room when operating 5 DO NOT position the heater alongside a wall or near curtains and other flammable materials The following minimum distances should be used 20cm from sides 150cm from front ALWAYS face heater towards center of room placing on a surface where it can twist on its castors if knocked by a child or dog etc ...

Page 7: ...ocouple f Check electromagnetic valve by gas engineer 4 After changing to maximum position with all three plaques alight One or more plaques appear below normal intensity a Blocked jets b Partially blocked supply tube a Remove and clean blocked jet b Remove supply tube remove jets and blow through the tube 5 Difficulty in cross lighting from position 1 to position 2 or 3 a Air draught directed awa...

Page 8: ... streetwizeaccessories com M17 1RY Specifications Heat Load 1 4Kw min 2 8Kw mid 4 2Kw max Heating Area 60 cubic metres Gas Consumption 110g hr min 200g hr mid 305g hr max Gas flameout ODS Anti tilt safety features Piezo electric ignition switch 3 Pce ceramic heating plates with safety grill Includes hose clips x2 LW638 Red Gas Type Butane Gas Pressure 28 35 mBar Quantity 1 Pce Weight 8 5Kg Product...

Reviews: