26
Disassembly
– Turn off the device while warm and disconnect from the power supply.
– Remove the
welding shoe (8)
with the
welding shoe holder (34)
by unfastening the
clamp screws (35)
from
the
extruder nozzle (32).
– Every time the welding shoe is changed, clean the
extruder nozzle (32)
of welding residue and make sure that
it is screwed in tightly.
– Remove
welding shoe (8)
from the
welding shoe holder (34)
by unfastening the
fastening screws (33).
Assembly
– Fasten a
welding shoe (8)
, appropriate to the welding seam, onto the
welding shoe holder (34)
with
fastening screws (33).
– The
welding shoe (8)
and
welding shoe holder (34)
must be tightened properly with the
clamp screws (35).
Danger – can cause burns!
Only work with heat-resistant gloves.
The welding shoe must be changed while the device is still warm from operation.
8
Welding shoe
32
Extruder nozzle
33
Fastening screw
34
Welding shoe holder
35
Clamp screw
35
8
Welding direction
The
welding shoe (8)
can be turned infinitely to the
desired welding direction by loosening the
clamp
screws (35)
.
The
clamp screws (35)
must be tightened well again
afterwards.
8
33
32
35 34
35
8
8
8
Changing the welding shoe
To disassemble the
hot air duct (44)
, first remove the
welding shoe (8)
. After loosening
the locked
fastening screw (45)
on the
pipe clip (10)
and the
clamp screw (47)
on
the hot air duct connector, the entire unit can be pulled out.
Assembly in reverse order.
8
44
45
10
47
Changing the hot air duct