• Use an air filter, if air is dusty.
• Air flow can be adjusted by the LEISTER air flow adjuster.
Compressed air
• When using compressed air, an oil and water filter must be connected.
• Air flow can be adjusted by air flow adjuster.
Operating conditions
• Fit appropriate nozzle as required.
• Connect air supply with corresponding
hose connection (7).
• Adjust air flow by means of air flow adjuster or pressure reducing valve.
ATTENTION: Keep minimum required air flow according to data on page 2.
• Connect tool to the mains.
• Adjust hot-air temperature by use of the red potentiometer.
• Internal electronic system controls the temperature according to the SET values.
• Display will blink until 20°C before reaching the SET value.
• Let the tool cool down after use!
Change of nozzle
• Let the tool cool down before changing the nozzle.
• Do not touch hot nozzle and only lay it on heat resistant surface because of fire
hazard.
• Nozzles can easily be screwed (M14) onto the heat protection tube.
• Use only LEISTER nozzles.
OPERATION
AIR SUPPLY
-4-
USAGE
Welding-Pen R