Electrical safety: double insulated
-2-
TEST SIGNS
TECHNICAL DATA
Voltage
V~
100
120
230
Frequency
Hz
50/60
50/60
50/60
Capacity
W
450
600
1000
Temperature °C
20 – 600
20 – 600
20 – 600
Air flow
l/min.
> 40
> 40
> 40
Air pressure
Pa
max. 10
5
(dynamic)
Weight
g
1000 with 3m cable, air hose and Y-connection
Size
mm
ø 32/43
×
270
Mains voltage cannot be switched over
This tool is
CCA
certificated (
C
ENELEC
C
ertification
A
greement).
Danger to life
when opening the tool, as live components
and connections ar exposed. Unplug the tool before
opening it.
Incorrect use of hot air blowers can cause
fire and
explosion hazard
, especially near combustible materials
and explosive gases.
The tool must be operated
with supervision
. Warmth can
reach combustible materials, which are out of sight.
For personal protection on building sites we
strongly
recommend
the tool be connected to a
GFCI
(
G
round
F
ault
C
ircuit
I
nterrupter) or a
RCCB
(
R
esidual
C
urrent
C
ircuit
B
reaker) .
The
voltage rating
stated on the tool must correspond to
the line/mains voltage.
Do not touch the element housing and nozzle when they
are hot as they can cause
burns
. Let the tool cool down.
Do not point hot air flow in the direction of people or
animals.
Protect tool from
damp
and
wet
.
FI
120
230
WARNING