background image

The voltage rating stated on the tool must correspond
to the line/mains voltage.

120

230

TECHNICAL DATA

Voltage

V~

Power consumption W

Temperature

°C

Air flow

l/min.

Air pressure

Pa

Emission level

L

pA

(dB)

Weight

kg

Size (L

××  

ø)

mm

Mark of conformity

Mark of approval

Certifcation scheme

Protection class II

120,  200, 230,   230 for 50/60 Hz

2700, 3000, 2300, 3400

20 – 650, steplessly adjustable

max. 350, manual air slide

2500

65

1.5 with 3m power supply cord

320 

×

64

¬

CCA

2

Line/mains voltage cannot be switched over

CAUTION

Danger to life

when opening the tool, as live compo-

nents and connections are exposed. Unplug the tool
before opening it.

Incorrect use of hot air blowers can cause 

fire and

explosion hazard,

especially near combustible materials

and explosive gases.

The tool must be operated 

with supervision

. Warmth

can reach combustible materials, which are out of sight.

Do not touch the element housing and nozzle as long as
they are hot since they can cause 

burns.

Let the tool

cool down. Do not point hot air flow in the direction of
people or animals. 

Protect the tool from 

dampness

and 

wet

.

WARNING

Summary of Contents for Mistral

Page 1: ... warming up processes Shrinking and welding of packaging foils and moulds Activating and releasing of solvent free glues and fusion adhesives Sterilisation of packaging materials such as small bottles corks and containers Smoothing of tablet coatings glazing of chocolate and cosmetic articles Separating and fusing of synthetic threads and fabrics Soldering processes on metal parts Removal of plast...

Page 2: ...20 64 CCA 2 Line mains voltage cannot be switched over CAUTION Danger to life when opening the tool as live compo nents and connections are exposed Unplug the tool before opening it Incorrect use of hot air blowers can cause fire and explosion hazard especially near combustible materials and explosive gases The tool must be operated with supervision Warmth can reach combustible materials which are...

Page 3: ... filter 7 Rubber stand 8 Heater tube 6 8 5 7 2 3 4 1 3 OPERATION Leister MISTRAL Assembling Assembly must ensure that only cold air is supplied no hot air backup occurs the tool is not subjected to a hot air flow from another tool The tool is protected against mechanical vibration and shaking Assembly dimensions in mm MISTRAL ...

Page 4: ...ol down the tool after use Change of nozzles reflectors Before changing nozzles reflectors allow the tool to cool down or use only combination pliers Do not touch hot nozzle reflector and make sure to put it only on a heat resistant surface because of the fire hazard The nozzles reflectors are easily pushed onto the conical heater tube 8 and are then secured by fastening the screw on the clamp Onl...

Page 5: ... damages Repairs have to be carried out by authorised Leister Service Centres only They guarantee a specialized and reliable repair service within 24 hours using original Leister spare parts Guarantee and liability are in accordance with the guarantee certificate as well as with the currently valid general business and sales conditions Leister Process Technologies rejects any guarantee claims for ...

Page 6: ...Leister Process Technologies Riedstrasse CH 6060 Sarnen Switzerland Tel 41 41 662 74 74 Fax 41 41 662 74 16 www leister com sales leister com ...

Reviews: