Incorrect use of hot air blowers can cause
fire and
explosion hazard
, especially near combustible materials
and explosive gases.
The tool must be operated
with supervision
. Warmth
can reach combustible materials, which are out of sight.
For personal protection on building sites we
strongly
recommend
the tool be connected to a
GFCI
(
G
round
F
ault
C
ircuit
I
nterrupter) or a
RCCB
(
R
esidual
C
urrent
C
ircuit
B
reaker) .
The
voltage rating
stated on the tool must correspond to
the line/mains voltage.
EN 61000-3-11; Z
max
= 0.047
Ω
+ j 0.029
Ω
. If necessary,
consultate supply authority.
Do not touch the element housing and nozzle when
they are hot as they can cause
burns
. Let the tool cool
down. Do not point hot air flow in the direction of
people or animals.
Protect tool from
damp
and
wet
.
FI
120
230
CAUTION
Electrical safety Double insulated
Voltage
V~
Frequency
Hz
Power consumption
W
Temperature
°C
Air flow
(20 °C)
l/min.
Air pressure
mbar
Emission level
L
pA
(dB)
Weight
kg
Size
mm
The tool is
CCA
certified (
C
ENELEC
C
ertification
A
greement).
2
TECHNICAL DATA
230
230
380 – 440
120
100
50/60
50/60
50/60
50/60
50/60
3700
3100
4000 – 5400
2300
2000
650
800
620
560
450
550
350
600
450
450
200
200
200
200
200
53
53
53
53
53
2.9
3.2
3.2
3.2
3.2
310
×
72
×
99
350
×
172
×
99
1 mbar = 100 Pa
Danger to life
when opening the tool, as live compo-
nents and connections are exposed. Therefore, before
opening it, disconnect all poles from the mains.
WARNING
APPROVAL MARK