26
• If a malfunction occurs in the unit, a message accompanied by an error code will appear on the
display (10)
.
This code stands for a more precise definition of the error (see table)
• An error can be reset by pressing the
function button (2)
for 3 seconds.
Error
Display
Designation
Cause of error
Troubleshooting
Err 01
Unit temperature too
high
Ambient temperature higher than
specified
Inlet air temperature higher than
specified
Air inlet blocked
Stainless steel filter blocked
Air outlet blocked
Incorrect nozzle installed
Reduce ambient temperature
Reduce inlet air temperature
Check air inlet
Clean stainless steel filter
Check air outlet
Monitor nozzle
Err 02
Heating element
temperature
too high
Air inlet blocked
Stainless steel filter blocked
Air outlet blocked
Incorrect nozzle installed
Check air inlet
Clean stainless steel filter
Check air outlet
Replace nozzle
Err 03
Temperature probe
Temperature probe connection
faulty
Temperature probe defective
Monitor the connection of the
temperature probe
Contact Leister service point
Err 04
Err 05
Err 06
Err 07
Err 08
Contact Leister service point
Summary of Contents for HOTWIND PREMIUM
Page 3: ...3 Type 800 C Type 800 C Type 800 C Type 800 C HOTWIND Size mm...
Page 119: ...119 3 2 1 w M5 P 9 F Leister 6 g Y IJ _ 7 x GE t 1 2 2 1 3mm 120 230 120 230 120 230 kq Z 2 U...
Page 122: ...122 10 W b 2 Reset Err 01 Err 02 Err 03 Leister Err 04 Err 05 Err 06 Err 07 Err 08 Leister...
Page 124: ...124 J EN 61000 3 11 Zmax 0 053 j 0 033 FI 120 230...
Page 131: ...131 3 2 1 M5 3 9 Leister 6 1 2 2 1 3mm 120 230 120 230 120 230 2...
Page 134: ...134 10 2 3 Err 01 Err 02 Err 03 Leister Err 04 Err 05 Err 06 Err 07 Err 08 Leister...