Leister FUSION 2 Operating Instructions Manual Download Page 2

Please read operating instructions carefully before 
use and keep for further reference.

Operating Instructions 

(Translation of the original operating instructions)

Leister FUSION 2/3C/3

Extrusion Welder

GB

DANGER!

 

Danger when opening up the tool, as live components and connections are 
exposed. Therefore, before opening it, unplug the tool to ensure disconnection 
from the mains. Electronically conductive material (eg PE-EL) must not be welded.

Incorrect use of the hand extruder (eg overheating of the material) can present a 

fire and explosion hazard

, especially near combustible materials and explosive 

gases.

Danger – can cause burns!

 Do not touch bare metal parts and emerging 

material while hot. Allow the device to cool. Do not direct stream of hot air or 
emerging material towards people or animals.

Warning

The tool must be operated 

under supervision.

 Heat can ignite flammable 

materials which are not in view.The machine may only be used by 

qualified 

specialists

 or under their supervision. Children are not authorized to use 

this machine.

For personal protection on building sites we 

strongly recommend

 the tool be 

connected to a 

RCCB

 (

R

esidual 

C

urrent 

C

ircuit 

B

reaker) .

Protect tool from 

damp

 and 

wet

.

FI

Caution

Application

Welding PE and PP thermoplastics for applications in

• container engineering

• pipeline construction

• plastic fabrication

•  landfill sites and abandoned polluted areas

The 

voltage rating

 stated on the tool must correspond to the mains voltage.

If power failure occurs, the hot air blower switch and drive must be switched off 
(release locking device).

120

230

Summary of Contents for FUSION 2

Page 1: ...FUSION 2 3C 3 Fusion 2 Fusion 3C Fusion 3...

Page 2: ...hot Allow the device to cool Do not direct stream of hot air or emerging material towards people or animals Warning The tool must be operated under supervision Heat can ignite flammable materials whi...

Page 3: ...mm FUSION 3 3 4 mm FUSION 3 4 5 mm Welding rod mm in accordance with DVS 2211 4 0 3 3 4 0 3 4 5 0 3 3 4 0 3 4 5 0 3 3 Welding output kg h Average values at 50 Hz PE 2 0 2 5 PP 1 8 2 3 PE 2 0 2 5 PP 1...

Page 4: ...off switch 5 Welding shoe 6 Welding rod opening 7 Extrusion rate regulation potentiometer 8 Tool rest 9 Handle 10 Tool handle 11 Drive unit 12 Hot air blower 13 Power supply cord 14 Air slide 15 Air i...

Page 5: ...2 up to 19 2 5 20 50 4 0 Starting protection The tool is equipped with current overload protection The drive switches off automatically if current consumption is too high The drive can for example not...

Page 6: ...entiometer 7 as required In case of a prolonged welding process the drive on off switch 4 can be held in the active state with the locking device 3 The welding rod is pulled in through the welding rod...

Page 7: ...extruder nozzle 19 of welding residue and make sure that it is screwed in tightly Remove welding shoe 5 from the welding shoe holder 17 by unfastening the fastening screws 20 Assembly Fasten a weldin...

Page 8: ...urs brushes Hot air blowers ca 1000 hours brushes Repairs should only be carried out by authorized Leister Service Centres They guarantee a specialised and reliable Repair Service within 24 hours usin...

Page 9: ...Your authorised Service Centre is Copyright by Leister Allied Power Tools 12 76 Rushdale St Knoxfield VIC 3180 Australia T 61 3 9764 2911 E sales alliedpowertools com au W www alliedpowertools com au...