10
14
14
16
15
9
1. Standard with hose connection fitted (9).
2. Plug connector coupling (available as accessory):
Remove the standard
hose connection (9)
and fit
the
plug connector (15)
on the
AIRSTREAM 100
instead.
Use an open-end wrench size 22 Insert the
hose plug adapter (16)
into the free end of the air
hose. Then it is imperative to install the supplied
hose
clamp (14).
Now plug the hose with the installed
hose
plug adapter (16)
into the
plug connection (15).
To
loosen the connection, press the black plastic element
on the
plug connection coupling (15)
and then pull
the hose.
Insert the free end of the air hose over the
hose con-
nection (9).
Then it is imperative to install the supplied
hose clamp (14).
Use one of the following two variants for the air supply of your externally operated hot-air welder on your
AIR-
STREAM 100
:
8.1. Hose connection
Caution–risk of burning:
The parts in the area of the air connection can get very hot during longer
operation and in particular at increased ambient temperature. In this case, touch the parts with
caution.
8. Assembly