TS12P, Technical Data
61
7.5
Automatic Target Aiming ATR
Range ATR/LOCK
ATR accuracy with
the GPR1 prism
System accuracy
with ATR
• The accuracy with which the position of a prism can be determined with Automatic
Target Aiming (ATR) depends on several factors such as internal ATR accuracy,
instrument angle accuracy, prism type, selected EDM measuring program and the
external measuring conditions. The ATR has a basic standard deviation level of
± 1 mm.
• The following graph shows the ATR standard deviation based on three different
prism types, distances and instrument accuracies.
Reflector
Range ATR mode
Range Lock mode
[m]
[ft]
[m]
[ft]
Standard prism (GPR1)
1000
3300
800
2600
360° prism (GRZ4, GRZ122)
800
2600
600
2000
360° Mini prism (GRZ101)
350
1150
200
660
Mini prism (GMP101)
500
1600
400
1300
Reflector tape
60 mm x 60 mm
45
150
not qualified
Machine Automation power prism
(MPR122)
For Machine Control
purposes only!
600
2000
500
1600
The maximum range can be restricted by poorer conditions, for example rain.
Shortest measuring distance: 360° prism ATR:
1.5 m
Shortest measuring distance: 360° prism LOCK:
5 m
ATR angle accuracy Hz, V (std. dev. ISO 17123-3):
1 " (0.3 mgon)
Base Positioning accuracy (std.dev.):
± 1 mm
Leica GRZ4 prism (360°)
Leica GRZ122 prism (360°)
20
mm
m
18
16
14
12
10
8
6
5”
3”
2”
1”
4
2
0
0
100
200
300
400
500
600
700
800
GRZ4
GRZ122
003744_001