Rugby 820/830, Troubleshooting
42
Troubleshooting
Problem
Possible Cause(s)
Suggested Solutions
The Rugby is
working, but not
self-levelling.
The Rugby is in Manual Mode.
The Rugby must be in Auto-
matic Mode to self-level. Set
the Rugby to Automatic Mode
by pressing the Auto-
matic/Manual Mode button.
– In Automatic Mode the X-
axis LED and the Y-axis LED
flash green while levelling.
– In Manual Mode the X-axis
LED and/or the Y-axis LED
are red.
Rugby does not
turn on.
The batteries are low or dead.
Check the batteries and
change or charge the batteries
if necessary. If the problem
continues, return the Rugby to
an authorised service centre
for service.
The distance of the
laser is reduced.
Dirt is reducing the laser output. Clean the windows of the
Rugby and the receiver. If the
problem continues, return the
Rugby to an authorised service
centre for service.
The laser receiver
is not working
properly.
The Rugby is not rotating. It may
be levelling or in Elevation Alert.
Check for proper operation of
the Rugby.
Refer to the receiver
manual for more infor-
mation.
The receiver is out of usable
range.
Move closer to the Rugby.
The batteries of the receiver are
low.
Change the receiver batteries.
The Smart Target
feature is not
working.
The Rugby 820 and the receiver
have not been paired and
cannot communicate with each
other.
Pair the Rugby 820 and the
receiver. Refer to "4.4 Pairing
the Rod Eye 180 with the
Rugby 820" for more informa-
tion.
Only the Rugby 820 contains a
radio device and can be paired
to the Rod Eye 180.
Elevation Alert
function is not
working.
The Elevation Alert function is
disabled.
The Elevation Alert function is
enabled or disabled by
pressing the following button
combination:
With Rugby turned on and
rotating, press and hold the Up
and Down Arrow buttons. Then
press the Automatic/Manual
Mode button to enable or
disable the Elevation Alert
function. The Rugby beeps
once to indicate the change.