Rugby 820/830, Automatic Field Calibration
40
Step 3 - Rotate 90° and align to the first side of the Y-axis (Y+)
Step 4 - Rotate 180° and align to the opposite side of the Y-axis (Y-)
If the calibration process was successful, the X and Y LEDs will flash alternately three
times, the beeper will sound and the Rugby will then turn off.
If the Rugby does not complete the procedure as noted above, the procedure has
failed and must be repeated.
X-axis
LED
Y-axis
LED
X
Y
X-axis
status
Y-axis status Actions
Off
Flashing
red
Off
Y-axis is level-
ling
Wait until the first side
of the Y-axis is meas-
ured.
Green on Flashing
green
X-axis is
complete
Y-axis is half
complete
Rotate laser 180° until
the X-axis LED is again
flashing red.
X-axis
LED
Y-axis
LED
X
Y
X-axis
status
Y-axis status Actions
Off
Flashing
red
Off
Y-axis is level-
ling
Wait until the reverse
of the Y-axis is meas-
ured.
Green on Green on
X-axis is
complete
Y-axis is
complete
Done.
004742_001
30 m (100 ft)
Y+
004743_001
30 m (100 ft)
Y—