abnormal use, and before, during and after important 
measurements.
Make sure the Leica DISTO™ optic is kept clean and 
that there is no mechanical damage to the bumpers.

CAUTION:

In using the instrument for distance measure-

ments or for positioning moving objects (e.g. cranes, 
building equipment, platforms, etc.) unforeseen 
events may cause erroneous measurements.

Precautions:

Only use this product as a measuring sensor, not as 
a control device. Your system must be configured and 
operated in such a way, that in case of an erroneous 
measurement, malfunction of the device or power 
failure due to installed safety measures (e.g. safety 
limit switch), it is assured that no damage will occur.

Switching on/off

1x briefly: the instrument and the laser are 
switched on.

The display shows the battery symbol 

 until 

the next button is pressed.

Pressing this button for longer switches the 
instrument off.

The instrument switches off automatically after 
three minutes of inactivity.

Setting the unit

Press long until the desired unit is displayed.

Possible units:

CLEAR-Key

1x briefly: the last action is cancelled.

Distance

Area

Volume

1.

0.000 m

0.000 m²

0.000 m³

2.

0'0'' 

1

/

8

0.000 m²

0.000 m³

3.

0 in 

1

/

8

0.000 m²

0.000 m³

4.

0'0'' 

1

/

16

0.00 ft²

0.0 ft³

5.

0 in 

1

/

16

0.00 ft²

0.0 ft³

6.

0.00 ft

0.00 ft²

0.0 ft³

Summary of Contents for DISTO D210XT

Page 1: ...cial and environmental damage Important paragraphs which must be adhered to in practice as they enable the product to be used in a technically correct and efficient manner Intended Use Permitted uses...

Page 2: ...ies The manufacturers of non Leica accessories for the Leica DISTO are responsible for developing imple menting and communicating safety concepts for their products They are also responsible for the e...

Page 3: ...CE key 7 HISTORICAL MEMORY UNITS key 8 CLEAR OFF key Display 1 Laser ON 2 Reference front rear end piece tripod 3 min max display 4 Battery status 5 Area volume 6 Info symbol 7 Pythagoras 8 Historical...

Page 4: ...attery compart ment seals Operation Measuring Conditions Range Range is limited to 70 m At night or dusk and if the target is in shadow the measuring range without target plate is increased Use a targ...

Page 5: ...such a way that in case of an erroneous measurement malfunction of the device or power failure due to installed safety measures e g safety limit switch it is assured that no damage will occur Switchin...

Page 6: ...snaps in push the stop bracket with a little force to the right side the stop bracket can now be completely unfolded The device automatically recognises the measurement position and adjusts the follo...

Page 7: ...imum value Switching on continuous measurement see above The corresponding maximum and minimum values are displayed Functions Addition Subtraction Distance Measurement 1x briefly the next measurement...

Page 8: ...me appears in the summary line the last three measured values appear in interme diate lines 1 2 3 Press the button for longer to display additional room information such as circumference ceiling floor...

Page 9: ...is pressed for along time while measuring a distance maximum or minimum contin uous measuring is activated Indirect measurement determining a distance using 3 auxilliary measurements 2x briefly the s...

Page 10: ...e either displayed with or Error The following errors can be corrected Cause Correction 204 Calculation error Repeat procedure 252 Temperature too high Let device cool down 253 Temperature too low War...

Page 11: ...en tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful inter ference...

Page 12: ...product is a Class 2 Laser Product in accordance with IEC60825 1 2007 Radiation safety of laser products Class 2 Laser Products Do not stare into the beam or direct it unnecessarily at other persons...

Page 13: ...ste Care for the environment and take them to the collection points provided in accordance with national or local regulations The product must not be disposed with household waste Dispose of the produ...

Page 14: ...6114 EN D N S FIN DK SLO TR GR ROK RUS SK CZ H PL EST LT LV BG RO http www leica geosystems com treatment or received from your Leica Geosystems dealer All right reserved for changes drawings descript...

Page 15: ...uality Systems ISO standard 9001 and Environmental Management Systems ISO standard 14001 Total Quality Management Our commitment to total customer satisfaction Ask your local Leica Geosystems agent fo...

Reviews: