3.
Ensuring that no utilities are below, push
the Earth Pin into the ground and con-
nect the black cable to the Earth Pin.
☞
For more safety, we recom-
mend pushing the Earth pin
into the ground at an angle of
45 degrees.
☞
For best performance, position
the Earth pin and black cable
at 90 degrees to the suspect
direction of the utility.
14343_001
4.
Connect the red cable to the positive (+)
terminal on the trace rod.
14537_001
5.
Turn on the transmitter.
☞
Ensure that the Connection
Mode LED indicator is on and
the battery level of the trans-
mitter is adequate.
13279_001
6.
Select the required frequency and power
output.
To indicate that the tracing signal rea-
ches a good level, the Power Output LED
indicator and the audible tone change
from pulsed to continuous.
13280_001
7.
Set the locator to the required Signal
Transmitter frequency.
0016797_001
8.
Sweep the area until a signal is detected.
Pinpoint and trace the utility.
☞
Use the Numeric Peak Indicator
to identify the exact position
of the rod. The position is typ-
ically indicated by the maxi-
mum value.
0016812_001