4.
The adjustment process is done in the following steps:
1
.
Adjust the distance of the camera from the calibration
target.
2
.
Move left or right following the on screen instructions.
3
.
Fit the calibration target into the red frame shown on
screen.
4
.
Trigger the picture using the on screen Laser/Photo cap-
ture option.
5
.
Follow the on screen instructions to complete the pro-
cedure.
5.
After the adjustment process is complete, feedback is
provided to the user:
Device is calibrated. Select
OK
to finish.
The adjustment failed. Device is not calibrated. Select
Calib-
rate
to start the adjustment process again. Select
Later
to
postpone.
52
Check & Adjust