LEHMANN Primary Controller Operating Instructions Manual Download Page 4

BD

A Primar

y Con

tr

oller / Sec

ondar

y Con

tr

oller 22-02-17 (GB)

4

CARE & MAINTENANCE

 

U

Do not spill any liquid over or into the individual components of the lock, incl. primary controller and secondary 
controller 

 

U

Only clean the components of the locking system including the primary controller and secondary controller with a 
clean, soft and slightly damp cloth.

 

U

Do not use any cleaning agents containing abrasives or solvents, as these may damage the housing.

 

U

Treating any of the electronic and mechanical components improperly or in a any way other than described in these 
operating instructions may lead to malfunctions and the loss of warranty.

 

U

Replace defective components immediately or take them out of operation.

INTENDED USE

The primary and secondary controllers described in these instructions may only be used with components of the 
LEHMANN Captos system. Only by using LEHMANN Captos components it is ensured that the quality requirements 
are met and reliable operation is possible. The use of third-party components, such as cables, cannot guarantee 
reliable operation. Permitted system components are specified below:

Name

Function

Captos

Furniture / locker lock

Captos iCharge

Furniture / locker lock, Additionally with USB charging function for smartphones and tablets 
(USB-A) and RGB backlighting

Primary Controller

• Power supply to the locks
• Communication between locks and Lehmann Management Software LMS  
   (Transfer point to the customer‘s LAN)
• Communication between secondary controller and LMS

Secondary Controller

• Power supply to the locks
• Communication between locks and primary controller

Power supply

Power supply of a primary or secondary controller. When using Captos locks, one power supply 
unit can supply up to three controllers with power. When using Captos iCharge locks one power 
supply unit per controller is required.

Power cord

Connection between power supply unit and country-specific socket

Power connection cable

For power supply between a controller and a downstream controller instead of a power 
supply unit when using Captos locks (not possible with Captos iCharge locks!).

Connection cable

• 4-pole cable with RJ12 plugs
• Energy and data connection between locks and primary or secondary controller
• Data connection between controllers

LEHMANN Management 
Software „LMS Online“

Software for the administration and configuration of the Lehmann RFID locks. LMS is ope-
rated in the customer‘s IT infrastructure. LMS Online is a special LMS license for the use of 
functions in connection with Captos and Captos iCharge.

Master- and  
programming cards

To configure the locks if the LMS is not to be used

User cards

The transponders contain encrypted information and are equipped with individual access 
authorizations for the locks and serve as keys for authorized persons.
If transponders from third-party manufacturers are to be used, it is strongly recommended 
that LEHMANN carries out a compatibility and range check in advance.

Summary of Contents for Primary Controller

Page 1: ...ting from lock to controller recommendation 9 Connecting the controller 10 Emergency power supply 13 Firmware update of the controller Firmware update of the locks via the controller Disposal 14 www lehmann locks com Operating Instructions GB Primary Controller Secondary Controller For connecting the RFID locks Captos and Captos iCharge BDA Primary Controller Secondary Controller 22 02 17 GB Secon...

Page 2: ...ments for electrical installations must be considered Installation may only be carried out by qualified personnel Electric shock U Touching parts can lead to injuries from electric shock U Do not touch the terminals when the product is receiving power U The installation commissioning and maintenance of our devices must be carried out by appropriately qualified personnel In particular electrical co...

Page 3: ...Secondary Controller Nominal Voltage 12 VDC Power Supply external Power Supply 100 240 VAC 50 60 Hz 2 A 138 W max Operating temperature 5 C to 60 C Storage temperature 25 C to 70 C Interfaces Controller Primary to Server Ethernet Controller to Controller RS485 Controller to Locks RS485 Connectors Power KYCON KPPX 4P Controller Primary to Server RJ45 Controller to Controller RJ45 Controller to Lock...

Page 4: ...ocks and Lehmann Management Software LMS Transfer point to the customer s LAN Communication between secondary controller and LMS Secondary Controller Power supply to the locks Communication between locks and primary controller Power supply Power supply of a primary or secondary controller When using Captos locks one power supply unit can supply up to three controllers with power When using Captos ...

Page 5: ...er 1 1 1 1 1 CAPTOS iCharge max 24 per Controller CAPTOS max 24 per Controller 1 Kupplung Stecker zum Verbinden von zwei Daten Verbindungskabeln Primary or secondary controller if you want to switch to online operation at a later point in time at least one primary controller is required Power supply unit with Captos locks only required on every 3rd controller Data connection cable RJ12 Power conne...

Page 6: ... Controller Netzteil bei Captos nur an jedem 3 Controller CAPTOS iCharge max 24 pro Controller Daten Verbindungskabel RJ11 Strom Verbindungskabel Mini DIN Secondary Controller max 32 hinter einem Primary Controller LAN Kundenseitig CAPTOS max 24 pro Controller 1 3 4 3 CAPTOS iCharge max 24 pro Controller Kupplung Stecker zum Verbinden von zwei Daten Verbindungskabeln Power supply unit with Captos ...

Page 7: ...92 120 104 DIMENSIONS Primary Controller Secondary Controller Power cord Connection cable 7 2 500 2 4 7 2 500 2 4 All dimensions in mm Power supply 72 175 35 1 000 72 175 35 1 000 Power connection cable 5 000 14 14 1 800 Other variants with country specific plugs of the same length are available ...

Page 8: ...plug for connecting two data connection cables 26 96 14 48 16 75 8 1 16 13 19 49 26 96 48 75 26 96 1 75 8 1 16 13 19 49 2 14 48 16 75 DESCRIPTION OF THE INTERFACES Primary Controller Secondary Controller All dimensions in mm 192 4 104 1 192 4 104 1 4 192 1 4 192 104 1 ...

Page 9: ...binet out of its installation position and then to loosen the cables from the locks in the next step For example couplings cable connection sockets can be used to remove or replace individual cabinets from the cabinet wall without great effort Alternatively a correspondingly large cable loop can be laid with continuous cabling It should be absolutely avoided that cables are subjected to tensile st...

Page 10: ...wer supply Figure Secondary controller power connection Connecting the connection cable from the lock to the controller The locks are connected to the controller with connecting cables The connecting cables of the locks must not be shortened If the cable is too short a second connection cable can be used as an extension by means of a coupling Insert the RJ12 plug of the connection cables that come...

Page 11: ... with one power supply unit ATTENTION This function is only possible with Captos and not with Captos iCharge locks The controller is supplied with power via the 100 240V power supply unit If Captos locks are used only one power supply unit is required for up to three controllers In this case the first controller is connected to the power supply unit the two following controllers are connected to e...

Page 12: ...r online operation the primary controller must be connected to the customer s network LAN Only primary controllers can be connected with an Ethernet cable to the LAN and thus to the server on which the LEHMANN management software LMS is installed Several primary controllers can be used per project They are connected to the network separately Figure Connection of the Ethernet cable to the primary c...

Page 13: ...ocks cannot be opened or closed The locks do not open automatically in the event of a power failure Changes to the configuration or authorization are also not transferred during a power failure It is therefore recommended to consider an emergency power supply when planning the project with Captos or Captos iCharge locks The emergency power supply can be connected in the form of a UPS uninterruptib...

Page 14: ... the LMS operating instructions or the LEHMANN Firmware Updater software DISPOSAL Dispose of the controller in accordance with local regulations and guidelines FIRMWARE UPDATE OF THE LOCKS VIA THE CONTROLLER If the Captos and Captos iCharge locks are used in online operation a firmware update is carried out on the locks via the LEHMANN Management Software LMS if required This process takes place a...

Page 15: ...BDA Primary Controller Secondary Controller 22 02 17 GB 15 NOTES ...

Page 16: ...econdary Controller 22 02 17 GB 16 LEHMANN Vertriebsgesellschaft mbH Co KG Uphauser Weg 82 D 32429 Minden Fon 49 571 50 599 0 Fax 49 571 50 599 822 info lehmann locks com www lehmann locks com DIN EN ISO 9001 2015 zertifiziert ...

Reviews: