background image

BD

A Cap

tur

a 100 MIF

ARE® / 22020-06-29 (GB)

12

Programming the User Cards 

(only for “assigned use” mode) 

In “assigned use“ mode, a maximum of 250 different user cards can be programmed per lock. It is not possible to 
program user cards in “shared use“ mode. In “shared use“ mode, the lock can be opened and closed without first 
programming the user cards (see Closing and Opening, see below).

After programming, the user cards can open and close the lock.

Programming user cards

       

Hold the master card  
in front of the lock.

    

  

    

Hold the user card in  
front of the lock.  
The card is accepted and 
programmed. This process 
can be repeated to program 
multiple user cards.

  

    

Card is not accepted.

    

    

  

      

      

Hold the master card  
in front of the lock.

    

  

    

             

CLOSING AND OPENING

Closing

       

Hold the user card  
in front of the lock.

    

  

    

Opening

       

Hold the user card  
in front of the lock.

    

  

    

Summary of Contents for Captura 100 MIFARE

Page 1: ...ogramming the Master card 11 Programming the Master card Closing and Opening 12 Unauthorised Transponders cards Facility Manager Function Emergency Opening 13 Deleting Individual Transponder Cards Deleting All Transponder Cards 14 Changing Operating Mode 15 Deactivating and activating acoustic signals Resetting to factory settings 16 Activation and deactivation of automatic locking 17 Battery warn...

Page 2: ...ng cards or with the LEHMANN Management Software LMS These operating instructions describe how to use the locking system with master and programming cards The software LMS and the corresponding documents can be found at https lms lehmann locks com SAFETY PRECAUTIONS U U Pack the battery for the transport of the lock so that no short circuit can occur risk of explosion and fire U U When replacing t...

Page 3: ... fixed assignment between the transponder cards and the locks The user cards are programmed or deactivated at the lock by means of a master card The system thus allows the granting of selective access authority for an item of furniture e g cabinet so that only authorised persons with a transponder card have access A transponder card can be programmed simultaneously on multiple locks with Assigned ...

Page 4: ...e of an installation card is optional Master card For complete commissioning a master card must be programmed for both operating modes The master card is required for starting and terminating programming operations This also includes the programming of user cards in Assigned use mode The master card also enables the so called Facili ty Manager function and the emergency opening of the lock A maxim...

Page 5: ... 10 Lightpoint only optional 1 2 3 4 5 6 7 8 9 Door Sidewall DIMENSIONS Lock Captura All dimensions in mm SYSTEM COMPONENTS AND PACKAGE CONTENTS Please note that these operating instructions apply to different product versions The package content therefore depends on the respective product variant The product variants and mounting recommendations shown here are intended for wooden furniture with a...

Page 6: ...1 48 8 7 2 26 38 3 8 Front cover C1 for metallic surfaces All dimensions in mm 70 0 7 6 5 8 8 3 3 5 5 54 4 5 70 0 7 6 5 8 8 3 3 5 5 54 4 5 70 0 7 6 5 8 8 3 3 5 5 54 4 5 Locking pin unit SD Type A with ejector pin A1 52 0 2 5 2 5 3 1 0 4 5 4 2 5 4 3 0 3 8 5 7 1 1 2 20 3 7 19 3 7 65 7 5 5 2 1 52 0 2 5 2 5 3 1 0 4 5 4 2 5 4 3 0 3 8 5 7 1 1 2 20 3 7 19 3 7 65 7 5 5 2 1 The ejector pin A1 can only be i...

Page 7: ...s must be checked on a project basis 4 5 54 10 7 2 3 2 0 2 3 5 58 48 4 5 54 10 7 2 3 2 0 2 3 5 58 48 For an adequate fine adjustment of the locking pin an average dimension of 53 mm is recommended MOUNTING ON NON METAL SURFACES Mounting the lock with locking pin SD Type A e g for hinge doors Side wall Inside of the door Side wall Door Lightpoint O16 for material thickness of 16 21 mm Lightpoint O1...

Page 8: ... with locking pin SD Type B e g drawer All dimensions in mm Note that the lightpoint can be installed as an option Without a lightpoint only acoustic signaling is available Mounting the lightpoint C 3 1 7 1 4 5 54 27 Top Shelf inside view To be installed without tools ...

Page 9: ... i n r o d ß e i l h c S d n u a g e m 13 5 Door Implied screw on socket Center point for locking pin Required hole punch in the door Hole punch in the door Side wall with locking pin SD Type A 13 5 5 2 4x Thermoplastic screw 3x25 ATTENTION If no lightpoint is installed a sticker is recommended on the outside of the door centered behind the lock for correct positioning of the RFID transponder Usin...

Page 10: ...ng the lock in the furniture Inserting the battery Battery is inserted correctly in the battery compartment Optical signals Quick flashing Short flashing Long flashing Acoustic signals Short Long The RFID antenna is located on the back of the lock Always place the transponder straight and centered on the lock TIPS FOR THE FOLLOWING PROGRAMMING STEPS The last 5 seconds before the shutdown of the pr...

Page 11: ... master card for the first time Hold the master card in front of the lock PROGRAMMING THE MASTER CARD Irrespective of the desired operating mode a master card must always be programmed before further programming and operation Only one master card can be programmed per lock The programming of the master card can be carried out when the lock is closed as well as when it is open If the lock is closed...

Page 12: ...rst programming the user cards see Closing and Opening see below After programming the user cards can open and close the lock Programming user cards Hold the master card in front of the lock Hold the user card in front of the lock The card is accepted and programmed This process can be repeated to program multiple user cards Card is not accepted Hold the master card in front of the lock CLOSING AN...

Page 13: ... then closes automatically After this automatic closure authorised user cards can continue to be used in shared use mode as well as in assigned use mode The last 5 seconds before closing are indicated by optical and acoustic signals EMERGENCY OPENING In the event that one or all authorised user cards are currently not available an emergency opening can be effected with the master card Please note ...

Page 14: ...individual user cards Hold the master card in front of the lock Hold the user card to be deleted in front of the lock Hold the master card in front of the lock DELETING ALL TRANSPONDER CARDS only for assigned use mode The deleting process can only be carried out when the lock is open Should there be no authorised user card to hand first perform an emergency opening using the master card Deleting a...

Page 15: ...ming card set must be bought separately from LEHMANN Vertriebsgesellschaft mbH Co KG The cards are for universal use Changing the operating mode Hold the master card in front of the lock Hold the programming card P1 Mode in front of the lock Shared use mode is selected Shared use Hold the programming card P1 Mode in front of the lock again Assigned use mode is selected Assigned use Hold the master...

Page 16: ... RFID reader with the LED is mounted outside the item of furniture Otherwise neither visual nor acoustic signals are passed on to the users making programming and possibly also operation difficult Please note that the acoustic signals for the battery warning and for changing the operating mode cannot be deactivated The programming card set must be bought separately from LEHMANN Vertriebsgesellscha...

Page 17: ... function is activated the lock closes automatically after 5 seconds after opening the lock with an authorized transponder It is recommended to activate automatic locking after programming the transponders The function can be carried out by using the master card and the programming card P4 Auto Locking To do this the lock must be in the mode assigned use and in an open position If the operating mo...

Page 18: ...battery replacement in the event of reduced battery power The battery warning takes place in two phases The settings are saved even without a power supply e g in case of battery replacement or in case the battery should be completely empty Battery replacement should be carried out within 2 minutes Battery warning Phase 1 Before an action can be carried out closing opening programming a battery war...

Page 19: ...on the website www lehmann locks com if required e g for technical reasons You will receive further information on the implementation and installation together with the firmware update DISPOSAL Dispose the locking system in accordance with local regulations and guidelines Remove the battery and dispose them separately in accordance with the national regulations When disposing of partially discharg...

Page 20: ... MIFARE 22020 06 29 GB 20 LEHMANN Vertriebsgesellschaft mbH Co KG Postfach 26 20 D 32383 Minden Fon 49 571 50 599 0 Fax 49 571 50 599 822 info lehmann locks com www lehmann locks com DIN EN ISO 9001 2015 zertifiziert ...