background image

 

 

Nurse call and personal transmitter technologies 

– MediSwitch rehab technology – Emergency call systems – OEM adaptations    

www.lehmannweb.com

                             

 

Lehmann Electronic  Niederkassel

  

© 2019  

LE243 V1.06 EN      

P. 11 / 27                   

Tel: +49 2208 9492 0      Fax.: +49 2208 949232 

 

 

VARIOREC

®

        

     

                  

Instruction Manual

 

Wireless Emergency Call Technology

                   

VarioRec6

 Radio Receiver 

10 Programming Mode 

This mode is used to program radio transmitters to the receiver, to delete them from the receiver or to set the daily message monitoring.  

 

Functions in programming mode 

  Program / delete radio transmitters. 

  Activate / deactivate the daily message. 

  Delete all programmed radio transmitters. 

 

10.1 Navigating in Programming Mode 

Note: The radio receiver automatically reactivates the operating mode if there is no input for approx. 1 min.  

 
Image sequence: Navigating  

 

 

 

1

 

Press and hold the 

right-hand button 

when plugging 

 

Green 

flashing light 

Receiver is in 

programming mode  

 

Press and hold 

left-hand button 

 

Green 

Receiver is 

back in 

operating mode 

Activating the programming mode 

From programming mode 

back to operating mode 

Briefly press left-

hand button 

 

Green 

flashing light 

From programming 

mode back to  

operating mode 

From a submode back 

to the programming mode 

Summary of Contents for VarioRec6

Page 1: ...Lehmann Electronic Niederkassel Copyright 2019 www lehmannweb de VARIOREC Product Documentation Radio Emergency Call Technology Instruction Manual VarioRec6 Radio Receivers ...

Page 2: ...n the catalogue and the technical description and only in combina tion with devices of a different make and components recommended or authorised by Lehmann Elektronik The proper and secure operation of the product requires correct transport storage installation and mounting as well as careful handling and maintenance Trade marks All designations identified by the trade mark symbol are registered t...

Page 3: ...desirable result or state could occur if the corresponding instruction is not followed In the event of several levels of danger occurring simultaneously the warning corresponding to the highest level of danger is always used A warning by a warning triangle indicating possible personal injury may also include a warning relating to property damage Qualified personnel The associated device system mus...

Page 4: ... in the Operating Mode 9 9 2 Care Mode 10 10 Programming Mode 11 10 1 Navigating in Programming Mode 11 10 2 Programming Deleting Radio Transmitters 12 10 2 1 Programming Radio Transmitters 12 10 2 2 Programming of Radio Receivers Used for Special Functions 13 10 2 3 Deleting Radio Transmitters 14 10 2 4 Activating Deactivating Daily Message Monitoring 15 10 2 5 Deleting All Programmed Transmitter...

Page 5: ...iver 869 MHz1 VarioRec6 radio receiver 869 MHz1 with power supply unit Documentation VarioRec6 quick reference guide enclosure LE235 VarioRec6 instruction manual this document can be downloaded from our homepage LE243 1 The frequency can be found on the identification decal Various connectors are available Note While unpacking each shipment should be inspected for completeness and damage Note In t...

Page 6: ... V mains to which the respective power outlet is connected o During a voltage breakdown the radio receiver no longer receives calls o Power Failure Message If the radio receiver is de energised the relay releases and indicates the power failure to the call system 5 Operating Steps Below standardised pictograms are used for the various variants 5 1 Connecting the Radio Receiver Plug in the receiver...

Page 7: ...rence guide 6 2 Range of the Radio Link Important During initial putting into operation of the radio receiver adequate reception at the usage site must be checked at regular intervals More information is provided in the descriptions of the matching receivers 7 Initial Putting Into Operation Carry out the following steps before the initial putting into operation Check if the radio receiver connecto...

Page 8: ...call reception with call transmission Fault messages Reception blockage Battery low message No daily message System error message Care mode 9 2 Activate deactivate Plug in Monitoring Radio calls Vital messages Daily message Fault messages When inserting the plug press the button Programming mode 10 x Program delete radio transmitters Button Multiple reception fault message Activate deactivate Dele...

Page 9: ...ght The settings and the call system determine if and how errors are transmitted to the call system In systems with a separate fault channel the fault message will always be transmitted The messages will be displayed until they are acknowledged Note Call messages continue to be received and transmitted even after receipt of a fault message The most recent message will be indicated After acknowledg...

Page 10: ...sion is suppressed during timeout However the receiver continues to indicate Calls Fault messages Deactivating the care mode Briefly press any button otherwise the operating mode is automatically reset after the set timeout Image sequence Activating the care mode during operation resetting the care mode in advance Acknowledge one fault message has been received 1 Briefly press any button 2 Green R...

Page 11: ...amming mode Program delete radio transmitters Activate deactivate the daily message Delete all programmed radio transmitters 10 1 Navigating in Programming Mode Note The radio receiver automatically reactivates the operating mode if there is no input for approx 1 min Image sequence Navigating 1 Press and hold the right hand button when plugging 2 Green flashing light Receiver is in programming mod...

Page 12: ...ecial functions are transmitted only if the call system supports their transmission by auxiliary plug contacts Warning Always check the range of new transmitters after programming The exact procedure is described in the radio transmitter manuals Image sequence Programming radio transmitters Receiver is in programming mode 2 Green flashing light Briefly press right hand button 5 The new radio trans...

Page 13: ... radio transmit ter has been pro grammed 6 Orange for 1 5 s 5 Briefly press middle button Receiver is in programming mode 2 Green flashing light Press and hold the right hand button when plugging 1 May be repeated for additional transmitters Briefly press left hand button 2 Green flashing light Receiver is in programming mode From submode back to programming mode Red flashing light This error mess...

Page 14: ...y press right hand button 5 Trigger radio call 3 Red flashing light This error message may have been caused by the following Several radio receivers trans mit simultaneously Radio interferences exist In both cases repeat the process Otherwise try to find the interference or try to repeat the programming procedure at another location Possible error message Red for 1 5 s 6 Radio transmiter has been ...

Page 15: ...ons Daily message active Depending on the call system a call fault message is generated if an expected daily message is not received Daily message deactivated Missing daily messages are ignored no monitoring Image sequence Activating deactivating daily messages for a radio receiver important the radio receiver must already have been programmed Receiver is in programming mode 2 Green flashing light...

Page 16: ...adio receiver are deleted Image sequence Deleting all programmed transmitters 3 Press and hold middle button Receiver is in deleting mode 4 Orange red flashing light Red for 1 5 s 6 All programmed transmit ters are deleted Receiver is in pro gramming mode 2 Green flashing light Press and hold the right hand button when plugging 1 8 Press and hold left hand button 0 Green Receiver is in operating m...

Page 17: ...Mode Activate deactivate Care Mode Set timeout 11 1 Navigating in Setup Mode Note The radio receiver automatically reactivates the operating mode if there is no input for approx 1 min Otherwise each actuation of the left hand button will access the next higher menu level until the operating mode is reached Figure Navigating in setup mode Press and hold the left hand button when plugging 1 2 Orange...

Page 18: ...ng indicator Important note The information mentioned above and below pertaining to the operating mode always refers to the activated state of the operating in dicator This manual does not contain image sequences applicable to the deactivated operating indicator The current state is indicated 3 Briefly press right hand button 4 Green flashing light Operating indicator is deactivated 4 Red flashing...

Page 19: ...ive The care mode is switched off Image sequence Activating deactivating the Care Mode The current state is indicated 6 Press and hold right hand button 6 Press and hold left hand button Changing the care state 2 Orange flashing light Receiver is in operating mode Orange green flashing light 5 Care mode is active Orange green flashing light for 7 Care mode is active 3 3 Briefly press right hand bu...

Page 20: ...out The current timeout is indicated 2 Orange flashing light Receiver is in setup mode Green Orange Red Green flashing light Orange flashing light Timeout 3 min 5 min 10 min 20 min 30 min Indicator 7 Briefly press left hand button 4 Briefly press right hand button 3 Briefly press right hand button Briefly press right hand button twice Press and hold left hand button 0 Green Receiver is in operatin...

Page 21: ...tters that are not to be used in care mode Sequence for cancelling the call suppression of all transmitters Deactivate the care mode This deletes all assignments of individual transmitters Image sequence Deactivating the call suppression in the care mode for individual transmitters with activated care mode 6 Press right hand button 2 Orange flashing light Receiver is in setup mode Orange green fla...

Page 22: ...eceivers are not received If all radio transmitters are to be received all previously programmed transmitters must be deleted see Delete all transmitters Image sequence Activating deactivating the master mode The current state is indicated 5 Press and hold right hand button 5 Press and hold left hand button 2 Orange flashing light Receiver is in setup mode Changing the state 3 Press and hold middl...

Page 23: ...ive all previously programmed transmitters will not trigger normal calls For exceptions see item 11 5 1 Functions Vital monitoring is active A call is trigged if no vital call is received within 24 hours Vital monitoring is deactivated Vital calls are ignored a vital message is not generated if no vital call is received Image sequence Activating deactivating the vital mode The current state is ind...

Page 24: ...trigger a call if the 24 h radio message of the assigned radio transmitter is not received Image sequence Deactivating ignoring vital mode monitoring of individual radio transmitters 6 Press and hold right hand button Green flashing light 2 Orange flashing light Receiver is in setup mode Green flashing light 5 Vital mode is active Ignore mode Press and hold the left hand button when plugging 1 8 T...

Page 25: ...ntrol 12 1 Resetting All Parameters to Factory Settings Image sequence Resetting all parameters to factory settings Putting the radio receiver in system mode Orange green flashing light 2 Receiver is in system mode Abort 7 Green Receiver is in operating mode 3 4 Orange red flashing light Press and hold right hand button 5 Briefly press any button Press and hold the middle button when plugging Rese...

Page 26: ... Dimensions 66 x 46 x 18 mm W x H x D plus length of connecting cable of approx 50 mm system dependent Temperature range 5 C to 55 C Weight approx 50 g Rating IP 63 Colour Housing similar to RAL 9016 traffic white Conformity CE RED RoHS II Accessory and replacement parts Accessory and replacement parts are available from your supplier Warranty The manufacturer is not liable for any damage resultin...

Page 27: ...sing the VarioRec6 radio receiver and matching radio transmitters must have the trained personnel status 20 1 Documentation The instructed person must be provided with at least one copy of this manual and the Quick Reference Guide LE235 for further refer ence 21 Disposal Instructions Used devices and batteries must not be disposed of together with domestic waste Dispose of used devices used batter...