background image

 

 

 

                                                               

INSTRUCTION MANUAL 

 

AAL Profiline alarm receiver  

 

HC-501-BA V1.05   Alarm receiver     Page 3 of 4 

AAL

 Homecare

          

Fon +49 2208 9339170           Fax +49 2208 9339063           www.aal-homecare.com

 

 

Fig. 5: Switching off a call 

 

Switching Off the Operating Indicator 

If the illuminated LED is regarded as disturbing (at night, for example), the green operating indicator LED can be switched OFF by 
pressing both buttons for approx. 5 seconds. It can be switched ON again by pressing both buttons for approx. 5 seconds. 

Error Indication 

A system fault is indicated by the operating indicator LED flashing in a 

red

 and 

green

 sequence. 

If the system fault is caused by another radio signal occupying the frequency band, the operating indicator LED flashes 

red

A “battery low” message of a programmed transmitter is indicated by the LED flashing 

orange

 and 

red

These messages can be switched off by pressing any button. 

 

 

 

Briefly operate the 

programmed shut-down 

transmitter

 

Fig. 6: Deleting all programmed transmitters and resetting all settings to factory settings 

All settings are reset to the delivery status and all 
already programmed transmitters are deleted. 

Or, if required, 

alternatively 

Briefly press the left- or 

right-hand button 

Press and hold

 the buttons, connect the 

device to a power outlet and 

continue to 

hold

 the buttons until a beep is heard. 

Summary of Contents for AAL Homecare Profiline HC-501

Page 1: ...itions Before using the device for the first time an interference free operation of the radio link should be ensured Proceed as follows 1 Switch on all electronic entertainment and communication devices e g television sets game consoles and computers in the immediate vicinity 2 Check if the radio message is received by the alarm receiver at a distance exceeding the intended usage distance by appro...

Page 2: ...nd battery messages internal acoustic alarm device Battery monitoring Battery low recognition Dimensions 50 x 110 x 40 mm W x H x D Weight Approx 130 g Protection class IP 30 Conformity CE RED directive RoHS directive Fig 3 Programming alarm transmitters1 Fig 4 Setting the signal type Press the right hand button for approx 3 seconds The green LED flashes Trigger a matching transmitter a hand held ...

Page 3: ...D flashing in a red and green sequence If the system fault is caused by another radio signal occupying the frequency band the operating indicator LED flashes red A battery low message of a programmed transmitter is indicated by the LED flashing orange and red These messages can be switched off by pressing any button Briefly operate the programmed shut down transmitter Fig 6 Deleting all programmed...

Page 4: ...d please contact your dealer or the following address AAL Homecare Deutschland Wahner Str 45 53859 Niederkassel Homepage www aal support Disposal Instructions Used devices and batteries must not be disposed of together with domestic waste Dispose of used devices used batteries and packaging material according to applicable laws and disposal regulations Conformity and Legal Provisions AAL Homecare ...

Reviews: