INSTRUCTION MANUAL
AAL Profiline alarm receiver
HC-501-BA V1.05 Alarm receiver Page 2 of 4
AAL
Homecare
Fon +49 2208 9339170 Fax +49 2208 9339063 www.aal-homecare.com
Cleaning
Use of a soft, slightly moist cloth with a small amount of cleaning agent, optionally with disinfecting agents according to EN 16615,
is recommended. Do not use abrasive cleaning agents.
Regular Measures
Caution
Carefully perform the periodic checks. Immediately replace worn / damaged parts. A damaged system or a system not
functioning properly must not be used until it has been repaired. Do not open the device.
Measures
We recommend a weekly inspection including triggering a test call and observing the signal LED message.
Specifications
Operating frequency:
869.2375 (safe social alarm frequency)
Operating voltage:
230 V AC
Indicators:
Signal and flash LEDs for alarm call and battery messages, internal acoustic alarm device
Battery monitoring:
“Battery low” recognition
Dimensions:
50 x 110 x 40 mm (W x H x D)
Weight:
Approx. 130 g
Protection class:
IP 30
Conformity:
CE (RED directive, RoHS directive)
Fig. 3: Programming alarm transmitters
1
Fig. 4: Setting the signal type
Press the
right-hand
button for approx. 3
seconds
The
green
LED flashes
Trigger a matching
transmitter, a hand held
transmitter, for example
Flash LED and signal transducer
(for interval see “signal transducer only”)
Signal transducer only
= 1 minute interval,
then 1 short signal per
minute
Flash LED only
Red
Pressing the right-hand button several times allows for setting
one of
three
alarm types.
1
A
shut-down transmitter
can be programmed as required. Proceed as described
above but use the
left-hand
button for programming. The
orange
/
red
LED flashes.
Briefly press the
left-hand
button to exit the program.
Briefly press the
right-hand
button to
exit the program.
The operating indicator LED is:
Green
Orange
/
red
The operation is
acknowledged by an