background image

 

 

 

                                                               

INSTRUCTION MANUAL 

 

AAL Profiline alarm receiver  

 

HC-501-BA V1.05   Alarm receiver     Page 2 of 4 

AAL

 Homecare

          

Fon +49 2208 9339170           Fax +49 2208 9339063           www.aal-homecare.com

 

 

Cleaning 

Use of a soft, slightly moist cloth with a small amount of cleaning agent, optionally with disinfecting agents according to EN 16615, 
is recommended. Do not use abrasive cleaning agents.  

Regular Measures 

 

 

Caution 

Carefully perform the periodic checks. Immediately replace worn / damaged parts. A damaged system or a system not 
functioning properly must not be used until it has been repaired. Do not open the device. 

 

 

Measures 

We recommend a weekly inspection including triggering a test call and observing the signal LED message. 

Specifications 

Operating frequency: 

869.2375 (safe social alarm frequency) 

Operating voltage: 

230 V AC 

Indicators: 

Signal and flash LEDs for alarm call and battery messages, internal acoustic alarm device 

Battery monitoring: 

“Battery low” recognition 

Dimensions: 

 

50 x 110 x 40 mm (W x H x D) 

Weight:   

 

Approx. 130 g 

Protection class:   

IP 30 

Conformity: 

 

CE (RED directive, RoHS directive) 

 

Fig. 3: Programming alarm transmitters

1  

 

 

 

Fig. 4: Setting the signal type 

Press the 

right-hand

 

button for approx. 3 

seconds 

The 

green

 LED flashes 

Trigger a matching 

transmitter, a hand held 
transmitter, for example 

Flash LED and signal transducer  

(for interval see “signal transducer only”)

  

 

Signal transducer only 
= 1 minute interval, 
then 1 short signal per 
minute 

Flash LED only                              

Red

 

Pressing the right-hand button several times allows for setting 
one of 

three

 alarm types. 

1

shut-down transmitter

 can be programmed as required. Proceed as described 

above but use the 

left-hand

 button for programming. The 

orange

/

red

 LED flashes. 

Briefly press the 

left-hand

 button to exit the program. 

Briefly press the 

right-hand

 button to 

exit the program. 

The operating indicator LED is: 

 

Green 

 

 

Orange

/

red

 

 

 

The operation is 
acknowledged by an 
acoustic signal 

Summary of Contents for AAL Homecare Profiline HC-501

Page 1: ...itions Before using the device for the first time an interference free operation of the radio link should be ensured Proceed as follows 1 Switch on all electronic entertainment and communication devices e g television sets game consoles and computers in the immediate vicinity 2 Check if the radio message is received by the alarm receiver at a distance exceeding the intended usage distance by appro...

Page 2: ...nd battery messages internal acoustic alarm device Battery monitoring Battery low recognition Dimensions 50 x 110 x 40 mm W x H x D Weight Approx 130 g Protection class IP 30 Conformity CE RED directive RoHS directive Fig 3 Programming alarm transmitters1 Fig 4 Setting the signal type Press the right hand button for approx 3 seconds The green LED flashes Trigger a matching transmitter a hand held ...

Page 3: ...D flashing in a red and green sequence If the system fault is caused by another radio signal occupying the frequency band the operating indicator LED flashes red A battery low message of a programmed transmitter is indicated by the LED flashing orange and red These messages can be switched off by pressing any button Briefly operate the programmed shut down transmitter Fig 6 Deleting all programmed...

Page 4: ...d please contact your dealer or the following address AAL Homecare Deutschland Wahner Str 45 53859 Niederkassel Homepage www aal support Disposal Instructions Used devices and batteries must not be disposed of together with domestic waste Dispose of used devices used batteries and packaging material according to applicable laws and disposal regulations Conformity and Legal Provisions AAL Homecare ...

Reviews: