3

Mounting Plate

Ceiling

Stem

Swivel Bracket

Mounting Wedge

Mounting plate

back view

European

3.5” 

Octagon

4” Octagon

4” Square

2 Gang

2 Gang

1 Gang

European

3.5”

Octagon

4” Octagon

4” Square

2 Gang

2 Gang

1 Gang

Mounting plate accommodates 

different size J-boxes

Sensor Params

LMPX-600

LMPC-600

Mode             Auto On

Blink              On

Load Type     Dim

LMBR-650

For networking

and managing

rooms, floors,

and building

(optional)

LMRC-611MCC

Wireless

Dimmer and/or

Scene Switch 

LMPX-600

Wireless

Sensor  

IPv6 Mesh for 

secure

networking

 of DLM 

rooms and devices 

over 6LoWPAN

Secure Bluetooth

low energy

communication for

mobile App support

DLM Configuration App

on a mobile device

WIRELESS ROOM CONNECTION

Stem

Swivel

Bracket

Snug

Ring

Unlocked

Locked

Mounting

Wedge

Mounting

Bracket

Ball Mount to J-Box

1.  Attach the mounting plate to the J-Box with the two included screws. 
2.  Attach the stem to the back of the swivel bracket by rotating the stem 

until secure.

3.  Attach the swivel bracket by rotating the stem into the center hole of the 

mounting plate until secure.

4.  Attach the mounting wedge to the mount end of the swivel bracket, 

using the included 10mm screw.

5.  Align the slots of the bracket to the ribs on the back of the LMPX-600. 

Then slide the LMPX-600 onto the mounting plate.

6.  Push snug ring towards plate to adjust sensor angle, then pull snug ring 

back towards sensor to lock in place.

Ball Mount to Ceiling

This method is ideal for mounting to a 

drop ceiling with ceiling tile.

1.  Cut a hole in the ceiling tile the 

same diameter as the stem. 

2.  Attach the stem to the back of the 

swivel bracket by rotating the stem 

until secure.

3.  Line up the center hole in the 

mounting plate with the hole in 

the ceiling. Then attach the swivel 

bracket by rotating the stem into 

the center hole of the mounting 

plate until secure.

4.  Attach the mounting wedge to the 

mount end of the swivel bracket, 

using the included 10mm screw.

5.  Align the slots of the bracket to the 

ribs on the back of the LMPX-600. 

Then slide the LMPX-600 onto the 

mounting plate.

6.  Push snug ring towards plate to 

adjust sensor angle, then pull snug 

ring back towards sensor to lock 

in place.

Switch

LMBC-650

Wireless

Network Bridge

LMBR-650

Border Router

LMPX-600

Wireless

Occupancy

Sensor

Line

Voltage

Room

Controller

(LMRC-112)

B

Line Voltage

Switched with

0-10 Volt control

Dimming Ballast

LED Driver, etc.

Load

Examples

(any relay)

A

Switched

etc.

B

Class 1 Dimming

(Class 2 also available)

Sensor Params

LMPX-600

LMPC-600

Mode             Auto On

Blink              On

Load Type     Dim

DLM Configuration App

on a mobile device

Note: 

the DLM config app

can only connect with the 

LMBC-650 to update firwmare.

You need an LMBR-650 and 

LMCS to commision a Hybrid

room.

Distance Recommendations:

30’ max between LMPX-600 and mobile device
60’ max. between LMPX-600 and room controller 

or bridge
10’ minimum and 100’ maxmimum between 

LMBR-650 and room controller or bridge

Summary of Contents for Wattstopper Series

Page 1: ...r Use Only Operating Temperature 32 to 104 F 0 to 40 C Storage Temperature 23 to 140 F 5 to 60 C Relative Humidity 5 to 95 non condensing Compliance Regulatory FCC RoHS Bluetooth certified UL and cUL listed E101196 Patent Pending Once paired to an LMRC 611 wireless room controller or LMBC 650 wireless bridge this unit is set for Plug n Go operation adjustment via the DLM Configuration App is recom...

Page 2: ...Attach the mounting wedge to the ceiling with the two included 1 mounting screws 2 Align the slots of the bracket to the ribs on the back of the LMPX 600 Then slide the LMPX 600 downward onto the mounting wedge Threaded Rod Mount The threaded rod adapter can mount to a 3 8 16 1 4 20 or 1 2 13 hanging threaded rod 1 Screw the adapter onto the rod 2 Attach the mounting wedge to the adapter using the...

Page 3: ...back towards sensor to lock in place Ball Mount to Ceiling This method is ideal for mounting to a drop ceiling with ceiling tile 1 Cut a hole in the ceiling tile the same diameter as the stem 2 Attach the stem to the back of the swivel bracket by rotating the stem until secure 3 Line up the center hole in the mounting plate with the hole in the ceiling Then attach the swivel bracket by rotating th...

Page 4: ...ll flash on all room controllers The first room controller placed into PtP will become the master 2 Pair the room controllers together Press the Config button once on each room controller This indicates to the rooms controllers that they will be paired with each other The master room controller s LED blink rate will double once the first device is paired to it This faster blink rate is convenient ...

Page 5: ...ND UNIT ADJUSTMENT USING THE DLM CONFIG APP The DLM Config App is available for both iOS and Android devices Search DLM Config on your device to download The app provides the ability to pair various devices in a room Additionally you can modify load binding and edit various DLM parameters for each device For details on the features and operation download the DLM Config App User Guide from the watt...

Page 6: ...NFORMACIÓN DE LA GARANTÍA FCC REGULATORY STATEMENTS This device complies with part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 this device must accept any interference received including interference that may cause undesired operation NOTE This equipment has been tested and found to comply with the limits for a Cla...