![LEGRAND VANTAGE RadioLink EasyTouch II ScenePoint DR Installation Download Page 3](http://html1.mh-extra.com/html/legrand/vantage-radiolink-easytouch-ii-scenepoint-dr/vantage-radiolink-easytouch-ii-scenepoint-dr_installation_1870934003.webp)
I N S T A L L A T I O N
©Vantage, 12/1/2016 / IS-0472-B
RadioLink® EasyTouch II ScenePoint DR — MODEL: RDR1XXX-XXXX
page 3 of 4
FCC ID: PII-RDS2000
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions: (1) This device may not cause harmful
interference, and (2) this device must accept any interference received,
including interference that may cause undesired operation.
NOTE: This equipment has been tested and found to comply with the
limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment
generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause
harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If
this equipment does cause harmful interference to radio or television
reception, which can be determined by turning the equipment off and
on, the user is encouraged to try to correct the interference by one or
more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that
to which the receiver is connected.
-
-
Consult the dealer or an experienced radio/TV technician for help.
Changes or modifications to this product not expressly
approved by
Vantage Controls could void the user’s authority to operate
this product.
Reset
The station stores the configuration data locally so that it will
continue to operate if communication with the system is lost. This
information includes: LED properties and sounder properties. To
reset this information to the factory default, press and hold
switches 1, 2 and 3 while power is applied to the station. The status
LED flashes briefly, indicating that the reset took place. After a
reset, the loads will be off and the LEDs will change to Blue for ON
and White for OFF. If the station was used as a Shade Controller
the
Full Open
and
Full Closed
positions must be re-learned by fully
opening and then fully closing the blind without stopping.
Removing Metal Tabs
Removal of metal tabs allows ganging with other ScenePoint
Stations or third party devices.
Diagnostic Information
The Status LED can be seen behind the sensor light bar. The sensor
bar is just between the bottom two buttons. The Status LED is off
or blinks 2, 3, 4 or 5 times followed by a pause to indicate status
information.
Off: The station is programmed and configured, or the station is
not powered, a line voltage connection has not been made or the
line feed breaker is off.
Two blinks: Station has logged on to Controller but is not
initialized. If two blinks persist more than five minutes, the station
should be reset. See Reset above.
Three blinks: Station is not added to the network. Verify that its
serial number has been programmed into the Controller and that
the station is within 100 Feet of the RFE1000.
Four blinks: Relay station problem. Please contact the factory.
Five blinks: Configuration mode.
Cleaning Buttons and Faceplates
Turn the breaker to the station OFF
Dampen a soft cloth in water and wring-out to barely
damp – almost dry
Use a light buffing motion to wipe clean
Do not take the station apart
Never spray station with any cleaners
ScenePoint Wiring Examples
Motorized Blind
Always disconnect power before wiring
the station and shade motor. In this
application the Interlock Switch is set to
active
or Interlocked. Connect load 1 to the
open relay of the blind motor and load 2 to
the close relay, or vice-versa. Typically,
neutrals are all tied together at the station
box. Custom program desired operation in
Design Center.
Fan and Light
Always disconnect power before wiring the
station and station loads. In this application the
Interlock Switch is set to inactive or the non-
interlocked switch position. Connect relay load 1 to
the light and relay load 2 to the fan, or vice-versa.
Typically, neutrals are all tied together at the station
box. Custom program desired operation in Design
Center.
NOTE: The light may not be dimmed in this
application.