Fixed trigger device 

 

Used to support the care of dementia patients 

 

Compatible with Reach IP, Advent XT2 & Carer Response 

 

Supplied with surface door contacts 

 

2 Position keyswitch 

 

Key removeable in both positions 

 

All units keyed alike (2 keys supplied)   

 

5 Year Lithium battery (typical)  

 

Low battery warning 

 

Operating Temperature: +5

o

C to +40

o

C  

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Digital Heartbeat 

 

Weight: 182 grams 

 

Dimensions: 87mm x 87mm x 40mm (HxWxD) 

 

Product Code: ZXT832 

 

 

The door alarm is used to activate an alarm call when a 
door is opened. If the door is opened with the keyswitch 
in the Normal position an alarm call will be transmitted. 
With the keyswitch turned to the Override position the 
door can be opened/closed without an alarm e.g. to allow 
access for a Carer visit.  

 

Positioning

 

The door alarm should be wall mounted outside the 
monitored door at a height where the key can easily be 
reached. The door contact should be mounted on the 
door frame and the magnet on the door.  

 

Operation

 

For dementia care applications, before entering the 
dwelling the keyswitch should be turned to the 

Override

 

position to prevent an alarm call when the door is opened. 
When leaving the dwelling, close the door and turn the 
keyswitch to the 

Normal

 position.

 

 

Alarm Condition

 

If the monitored door is opened (with the keyswitch in the 
Normal position), an alarm call will be transmitted. A new 
alarm will not be triggered until the door has been closed 
and opened again.  

 

Low Battery Condition

 

A low battery condition will be reported automatically to 
the Alarm Receiving Centre (ARC) or the local Manager. 
The door alarm should be replaced as soon as possible 
within 30 days. The door alarm can be returned to Tynetec 
for battery replacement.  

 

Out of Range Notification (Reach IP)

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed 
from an installation. Should the Reach IP be unable to 

detect a device’s heartbeat it will automatically generate a 
“radio out of range” notification. 

Firstly, investigate if 

there’s a genuine reason for the alert, if not, arrange for 

the peripheral device to be replaced immediately.  

The “Radio 

out of range t

imer” can be set from 30 hours to 

99999 hours in Pulse CMP. “Radio 

s

upervision” can be 

disabled by unchecking the tick box associated with each 
peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the door alarm once every month. 
Clean with a damp cloth, do not use solvents or cleaners 
on the door alarm. 

 

Disposal

 

Waste electrical products should not be disposed of with 
normal household waste. The door alarm is ideally suited 
for disposal within the waste electronic and electrical 
equipment (WEEE) recycling scheme.  
Please recycle where facilities exist.  
Check with your local authority or contact your supplier for 
recycling/disposal advice. 

 

Warning

 

The door alarm contains a Lithium battery. If tampered 
with the battery may be damaged and create a fire hazard.  
No attempt should be made to remove or replace the 
battery. Do not incinerate. 

 

 

 

 