Door Alarm & Keyswitch
869MHz
Caring for People
_________________________________________________________________________
________________________________________________________________
Doc No. FM0836 V1.01 Page 2
Mount the backbox
using 2 screws
through the rear
fixing holes “
A
”.
“
A
”
“
A
”
Magnet on
the door
Contact
on the
door
frame
10mm Max
Fix the contact to the door frame and route the
wire with the self-adhesive clips.
ZXT832
S:081923668
Iss-1
1093089F09
19W8
How to install the Door Alarm
The door alarm is designed for internal use only, it is not
suitable for external applications. Undo the 2 screws and
remove the door alarm backbox.
Note: maximum 10mm gap between the magnet and the
contact when the door is closed.
Telecare Radio ID
The door alarm includes a radio transceiver to
communicate with the Reach IP, Advent XT2
or Carer Response.
The Radio ID is a 10-digit
code printed on the
door alarm label...
Registering the Door Alarm onto a Reach IP
Login to Pulse CMP (www.tynetecpulse.com) and enter the
Reach IP Serial No. in the
ALARM UNIT
view. Press the
Accessories
button and enter the Radio ID code, Location
and Equipment type. Press
Save
then
Synchronize
.
IMPORTANT
: when the door alarm is installed a test call
must be made to check operation and start the digital
heartbeat.
Alternatively, with the Reach IP in normal operating mode
undo the fixing screw and remove the stand or connector
cover to access the
⚫
Power button.
Press the
⚫
Power button to enter Control Mode, then
press and hold the
button until the unit announces
“
add radio device
” then release.
Press the
⚫
button to confirm then activate the door
alarm by opening the door.
The Reach IP unit will sound a high beep if it’s a new
device and announce “
range test mode
”
.
Press
⚫
to confirm, or press
to step to the next
function, or press
to exit the mode.
Registering the Door Alarm onto an Advent XT2
Radio device programming can only be performed from
the Advent XT2 Manager’s Panel designated as the
Controller
. Login using the Manager or Engineer password
and touch the Programming button.
Select the
Program Radio Devices
option from the
Program Setting drop-down list.
Enter the
Radio ID:
this is the 10-digit code taken from the
label on the door alarm.
Enter the
Flat ID:
this is the flat number the door alarm is
being installed in. Enter 4-digits e.g. 0014.
Enter the
Location:
select where the door alarm is
located
from the drop-down list e.g. Front Door.
Press the
Send
button to update the XT2 system.
Activate the door alarm to check operation.
⚫
Power Button
Connect the door contact to
the door alarm with the
cable provided.