  Doc No. FM0836 V1.01 Page 2   

 

Mount the backbox 
using 2 screws 
through the rear 

fixing holes “

A

”.

 

A

 

A

 





Magnet on 
the door  

Contact 

on the 

door 

frame 

10mm Max 

Fix the contact to the door frame and route the 
wire with the self-adhesive clips. 

ZXT832

 

S:081923668  
Iss-1 

1093089F09

  

19W8

 

How to install the Door Alarm

 

The door alarm is designed for internal use only, it is not 
suitable for external applications. Undo the 2 screws and 
remove the door alarm backbox.  

 

 

 

 

 

 

 

 
 
 

 

 

 

 
 
 
 

 

 

 
 

 

 

 

Note: maximum 10mm gap between the magnet and the 
contact when the door is closed.

 

 

Telecare Radio ID

 

The door alarm includes a radio transceiver to 
communicate with the Reach IP, Advent XT2  
or Carer Response.

 

 

The Radio ID is a 10-digit  
code printed on the  
door alarm label...

  

 

Registering the Door Alarm onto a Reach IP

 

Login to Pulse CMP (www.tynetecpulse.com) and enter the 
Reach IP Serial No. in the 

ALARM UNIT

 view. Press the 

Accessories

 button and enter the Radio ID code, Location 

and Equipment type. Press 

Save

 then 

 

Synchronize

IMPORTANT

: when the door alarm is installed a test call 

must be made to check operation and start the digital 
heartbeat. 

 

Alternatively, with the Reach IP in normal operating mode 
undo the fixing screw and remove the stand or connector 
cover to access the 

 Power button. 

 

 

Press the 

 Power button to enter Control Mode, then 

press and hold the 

 button until the unit announces 

add radio device

” then release. 

 

Press the 

 button to confirm then activate the door 

alarm by opening the door.  

The Reach IP unit will sound a high beep if it’s a new 
device and announce “

range test mode

.  

Press 

 to confirm, or press 

 to step to the next 

function, or press 

 to exit the mode. 

 

 

Registering the Door Alarm onto an Advent XT2

 

Radio device programming can only be performed from 

the Advent XT2 Manager’s Panel designated as the 

Controller

. Login using the Manager or Engineer password 

and touch the Programming button.  
Select the 

Program Radio Devices

 option from the 

Program Setting drop-down list.

 

 

 
 
 
 
 
 
 
 
 
 

Enter the 

Radio ID: 

this is the 10-digit code taken from the 

label on the door alarm. 
Enter the 

Flat ID: 

this is the flat number the door alarm is 

being installed in. Enter 4-digits e.g. 0014. 
Enter the 

Location: 

select where the door alarm is

 

located 

from the drop-down list e.g. Front Door. 
Press the 

Send

 button to update the XT2 system. 

Activate the door alarm to check operation. 

 

Power Button 

Connect the door contact to 
the door alarm with the 
cable provided. 