Doc
No.
FM0460
issue
J
Page
6
Registering
a
Temperature
Extreme
Sensor
onto
a
Touchsafe
Pro
Nursecall
system
1.
Put
the
Touchsafe
Pro
Master
Panel
into
Telecare
registration
mode;
touch
the
screen
and
Logon
as
an
Engineer
or
a
Manager
(password
required),
then
from
the
main
menu
page
touch
the
Telecare
button
to
open
the
screen
shown
below…
2.
Enter
the
temperature
extreme
sensor
8
digit
ID’s…
3.
Press
the
Close
button
to
exit
Telecare
mode
and
the
Nursecall
panel
is
now
back
in
normal
operating
mode.
4.
Press
the
TEST
button
and
check
a
high
temperature
alarm
call
is
displayed
on
the
Nursecall
panel
like
below
followed
by
a
low
temperature
alarm
call
about
20
seconds
later.
Remember
to
remove
and
refit
the
battery
after
the
test
call.
The
screen
banner
is
red
for
high/low
temp
alarm
calls
(
Touch
the
banner
to
display
notes
).
A
high
or
low
temperature
alarm
call
cannot
be
accepted
or
silenced
from
the
screen.
You
must
visit
the
appropriate
Nursecall
Call
Point
to
cancel
the
call.
Deleting
a
Temperature
Extreme
Sensor
from
a
Touchsafe
Pro
Nursecall
system
Select
the
high
temperature
sensor
ID
to
be
deleted
from
the
Delete
Telecare
Device
pull
‐
down
list
box
(prefixed
“T41”).
Details
of
the
sensor
selected
will
be
displayed
in
the
Room
,
House
Code
and
ID
boxes
below.
If
the
details
shown
are
correct
press
the
Delete
button.
Select
the
low
temperature
sensor
ID
to
be
deleted
from
the
Delete
Telecare
Device
pull
‐
down
list
box
(prefixed
“T42”)
Repeat
as
above
and
press
the
Close
button
to
exit.
Refer
to
the
Touchsafe
Pro
Display
Panel
user
guide
(Doc
No.
FM5505)
provided
with
the
Nursecall
system
for
more
information.
Tynetec
and
Aidcall
operate
a
policy
of
continuous
improvement
and
reserve
the
right
to
change
product
specifications
without
notice.
If
any
variation
to
the
details
contained
in
this
document
are
suspected
please
contact
Tynetec’s
customer
support
dept
on
01670
352371.
The
8
digit
ID’s
are
made
up
of
the
2
digit
device
type
code
(High
Temp
=
41
&
Low
Temp
=
42)
followed
by
the
6
digit
unit
ID
which
can
be
found
on
a
label
on
the
back
of
the
sensor.
Touch
the
Add
Telecare
Device
box
then
use
the
on
‐
screen
keypad
to
enter
the
high
temp
ID.
Hint:
enter
a
zone
in
the
Filter
box
to
narrow
the
search
for
the
room
(see
below).
Select
the
users
Call
Point
ID
from
the
Room
pull
‐
down
list
box
then
press
Save
.
Note:
this
is
the
room
unit
that
will
be
will
be
used
to
cancel
the
call.
Touch
the
Add
Telecare
Device
box
again
and
repeat
as
above
but
this
time
enter
the
low
temp
ID
i.e.
42
followed
by
the
same
6
digit
ID
from
the
label
.
Use
keypad
to
enter
8
digit
ID’s*
here
Select
the
relevant
Call
Point
ID
here
Save
when
done
Close
to
exit
mode
On
‐
screen
keypad
CALLING
CANCEL
HC
345
ID
001
Press
the
LIGHT
GREY
button
to
cancel
the
call
*Note:
both
high
and
low
temperature
ID’s
must
be
entered;
Prefix
41
=
High
Temp
and
Prefix
42
=
Low
Temp
ZXT426
W66265
Ser:
10151997
ID:
037233
EE1770
V1.05A
DR