Registering
a
Temperature
Extreme
Sensor
onto
an
Altec
Response
local
carer
alarm
unit
1.
Put
the
Altec
Response
unit
into
radio
device
learn
mode…
2.
Activate
the
temperature
extreme
sensor…
3.
Exit
the
Altec
Response
radio
device
learn
mode…
4.
Press
the
TEST
button
and
check
a
high
temperature
alarm
call
is
reported
on
the
Altec
Response
unit
followed
by
a
low
temperature
alarm
call
about
20
seconds
later.
Remember
to
remove
and
refit
the
battery
after
the
test
call.
Deleting
a
Temperature
Extreme
Sensor
from
an
Altec
Response
local
carer
alarm
unit
Press
ENTER
to
activate
the
wake
‐
up
display
then
ENTER
again
to
display
the
main
menu
Press
ENTER
to
select
Radio
Devices
Press
the
key
to
select
Delete
Device
then
press
ENTER
The
display
will
prompt
you
to
“
Trigger
the
Sensor
”
Press
the
TEST
button
on
the
temperature
extreme
sensor
to
be
deleted
‐
the
display
will
show
high
temp
and
its
41xxxxxx
ID
If
this
is
the
device
you
activated
press
the
key
to
select
Delete
then
press
ENTER
After
about
20
seconds
the
display
will
show
the
low
temp
and
its
42xxxxxx
ID
If
this
is
the
device
you
activated
press
the
key
to
select
Delete
then
press
ENTER
Note:
if
the
ID
is
NOT
the
device
you
activated
press
the
ENTER
key
to
select
Reject
then
try
again
To
exit
the
mode
select
Exit
then
press
the
ENTER
key.
Refer
to
the
Altec
Response
installation
guide
(Doc
No.
FM0548)
provided
with
the
portable
alarm
unit
for
more
information
on
programming
and
testing
radio
devices.
Press
and
hold
the
TEST
button
for
about
3
seconds
until
the
RED
light
starts
to
flash.
The
display
will
show
High
Temperature
and
its
41xxxxx
ID
number.
Check
the
ID
is
correct,
press
the
key
to
select
Accept
then
press
ENTER
.
Note:
if
another
device
has
been
picked
‐
up
press
ENTER
to
Reject
and
try
again
.
The
display
will
show
Flat
,
use
the
&
keys
to
choose
the
dwelling
type.
Press
the
key
to
select
No:
000000
then
press
the
ENTER
key.
Use
the
&
keys
to
select
each
digit
of
the
flat
number
and
the
&
keys
to
move
between
digits
then
press
the
ENTER
key.
Press
key
several
times
to
select
Exit
then
press
the
ENTER
key.
The
display
will
prompt
you
to
“
Trigger
the
Sensor
”
again.
After
about
20
seconds
the
display
will
show
Low
Temperature
and
its
42xxxxx
ID
number,
repeat
as
above.
IMPORTANT:
remove
the
battery
to
EXIT
TEST
MODE,
leave
for
a
few
seconds
then
refit.
Press
ENTER
to
activate
the
wake
‐
up
display
then
ENTER
again
to
display
the
main
menu.
Press
ENTER
to
select
Radio
Devices
Press
ENTER
to
select
Learn
Device
The
display
will
prompt
you
to
“
Trigger
the
Sensor
”.
You
now
have
20
seconds
to
activate
the
temperature
extreme
sensor.
From
the
Learn
Device
menu
select
Exit
then
press
ENTER
.
From
the
Radio
Devices
menu
select
Exit
then
press
ENTER
.
The
display
will
return
to
the
wake
‐
up
screen
and
go
blank
after
10
seconds.
The
Altec
Response
is
now
back
in
normal
operating
mode.