background image

Doc

 

No.

 

FM0460

 

issue

 

J

 

Page

 

1

  

169MHz

 

Telecare

 

Devices

 

Temperature

 

Extreme

 

Sensor

 

 

__________________________________________________________________________________________________________

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Compatible

 

with

 

Reach

 

at

home

 

alarms,

 

Advent

 

xt

 

warden

 

call,

  

Altec

 

Response

 

and

 

Touchsafe

 

Pro

 

Nursecall

 

systems

 

 

Solid

 

state

 

temperature

 

sensing

 

element

 

 

Lower

 

alarm

 

temperature:

 

5

o

C

 

+/

‐ 

2.5

o

C

 

for

 

30/60

 

minutes

 

 

Upper

 

alarm

 

temperature:

 

30

o

C

 

+/

‐ 

2.5

o

C

 

for

 

5/10

 

minutes

 

 

Rate

 

of

 

rise

 

alarm

 

temperature:

 

8

o

C

 

per

 

minute

 

 

User

 

replaceable

 

3.6V

 

AA

 

Lithium

 

battery

 

 

Low

 

battery

 

warning

 

 

Test

 

button

 

 

Dimensions:

 

84

 

x

 

84

 

x

 

36

 

mm

 

(HxWxD)

 

 

Weight:

 

102

 

grams

 

 

Product

 

Code:

 

ZXT426

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

What

 

are

 

Temperature

 

Extreme

 

Sensors

 

used

 

for?

 

 

The

 

temperature

 

extreme

 

sensor

 

will

 

provide

 

early

 

warning

 

of

 

extreme

 

low

 

or

 

high

 

household

 

temperatures

 

which

 

could

 

result

 

in

 

the

 

occupier

 

suffering

 

hypothermia

 

or

 

dehydration.

 

In

 

addition,

 

the

 

building

 

will

 

also

 

be

 

protected

 

against

 

burst

 

pipes

 

or

 

potential

 

fire

 

hazards.

 

 

Where

 

should

 

Temperature

 

Extreme

 

Sensors

 

be

 

fitted?

 

 

The

 

temperature

 

extreme

 

sensor

 

should

 

be

 

fitted

 

in

 

the

 

hallway

 

or

 

living

 

room.

  

It

 

should

 

be

 

wall

 

mounted

 

at

 

around

 

1.4

 

metres

 

above

 

floor

 

level

 

and

 

away

 

from

 

any

 

draughts

 

or

 

heat

 

sources.

 

 

Typical

 

Tools

 

Required

 

 

A

 

drill

 

and

 

screwdriver

 

are

 

not

 

required

 

if

 

the

 

self

 

adhesive

 

pad

 

is

 

used.

 

Always

 

make

 

sure

 

the

 

correct

 

drill

 

bits

 

and

 

screwdrivers

 

are

 

used.

 

 

Installation

 

 

Using

 

Screw

 

Fixings

 

 

1.

 

Remove

 

the

 

top

 

by

 

pulling

 

apart

 

from

 

the

 

back

 

section.

  

 

2.

 

Drill

 

the

 

back

 

section

 

as

 

required

 

and

 

fix

 

to

 

the

 

wall

 

using

 

the

 

screws

 

&

 

plugs

 

provided.

 

 

3.

 

Set

 

the

 

DIL

 

switches

 

&

 

links,

 

fit

 

the

 

battery

 

and

 

test

 

as

 

described

 

on

 

the

 

following

 

page

 

before

 

refitting

 

the

 

top

 

section.

 

 

 

Installation

 

 

Using

 

Self

 

Adhesive

 

Pads

 

 

1.

     

Remove

 

the

 

top

 

by

 

pulling

 

apart

 

from

 

the

 

back

 

section.

 

 

2.

 

Select

 

the

 

best

 

location

 

where

 

the

 

wall

 

is

 

clean,

 

dry

 

and

 

even.

 

 

3.

 

Stick

 

the

 

adhesive

 

pad

 

to

 

the

 

rear

 

face

 

of

 

the

 

back

 

section

 

and

 

press

 

firmly

 

to

 

the

 

wall

 

ensuring

 

it

 

is

 

stuck

 

securely.

 

 

4.

 

Set

 

the

 

DIL

 

switches

 

and

 

links,

 

fit

 

the

 

battery

 

and

 

test

 

as

 

described

 

on

 

the

 

following

 

page

 

before

 

refitting

 

the

 

top.

 

 
 
 
 
 
 
 

 
 
 
 
 

PULL

 

APART

TO

 

REMOVE

TOP

 

SECTION

 

FIX

 

BACK

 

SECTION

 

TO

 

WALL

 

Tynetec and

 

Aidcall

 

are business

 

units

 

of

 

Legrand

 

Electric

 

Ltd

Unit

 

10

 

Cowley

 

Road,

 

Blyth

 

Riverside

 

Business

 

Park,

 

Blyth

 

Northumberland,

 

NE24

 

5TF.

 

Tel:

 

01670

 

352

 

371

 

Fax:

 

01670

 

362

 

807

 

Email:

 

[email protected]

  

Web

:

 

www.tynetec.co.uk

Summary of Contents for Tynetec ZXT426

Page 1: ... or living room It should be wall mounted at around 1 4 metres above floor level and away from any draughts or heat sources Typical Tools Required A drill and screwdriver are not required if the self adhesive pad is used Always make sure the correct drill bits and screwdrivers are used Installation Using Screw Fixings 1 Remove the top by pulling apart from the back section 2 Drill the back section...

Page 2: ...ond pause followed by another 9 flashes the sensor transmits a high temperature signal followed by a low temperature signal Remove the battery to EXIT TEST MODE Leave for a few seconds then refit for NORMAL OPERATION The range of all radio devices can be affected by the working environment always take care during installation and perform several test calls Cleaning Care Temperature extreme sensors...

Page 3: ...s the key to exit Program Mode the unit will sound a Double Beep and the front light will return to STEADY GREEN The 6 digit ID can be found on a label on the back of the temperature extreme sensor The instructions given above for the standard Reach product also applies to the Reach Plus Reach Plus GSM and Reach Ultra models Refer to the instruction booklets provided with these products for more i...

Page 4: ...the Ready prompt then press the LINE key to clear the connection Refer to the Advent xt operators manual Doc No FM0420 provided with the warden call system for more information on programming and testing radio devices Using the Manager s DECT telephone Press the LINE key and wait for the Ready prompt Enter 5 0 0 0 followed by the key Enter the flat number the temperature extreme sensor is being in...

Page 5: ...o the Altec Response installation guide Doc No FM0548 provided with the portable alarm unit for more information on programming and testing radio devices Press and hold the TEST button for about 3 seconds until the RED light starts to flash The display will show High Temperature and its 41xxxxx ID number Check the ID is correct press the key to select Accept then press ENTER Note if another device...

Page 6: ...ature sensor ID to be deleted from the Delete Telecare Device pull down list box prefixed T42 Repeat as above and press the Close button to exit Refer to the Touchsafe Pro Display Panel user guide Doc No FM5505 provided with the Nursecall system for more information Tynetec and Aidcall operate a policy of continuous improvement and reserve the right to change product specifications without notice ...

Reviews: