Step 3: Connecting the Equipment
A. AC Power
To connect the power supply:
•
Attach the included AC power cord to the LX II and plug it into an AC power outlet.
B: Local Access Ports
To connect a local PC:
Attach a multi-sync VGA monitor, and USB mouse and keyboard.
C: Network Port
To connect the network:
•
Connect a standard Ethernet cable from the network port to an Ethernet switch, hub, or router.
D: Target Server Ports
To connect target servers:
1.
Connect the keyboard, mouse and video plugs on the CIM to the corresponding ports on the target server.
2.
Connect the CIM to an available target server port on the back of the LX II via a Cat5/5e/6 cable.
E: Modem Port (Optional)
See Configuring Modem Settings, in the
Online Help
.
QS Rule
Step 4: Configuring the LX II
For the following steps, you must change the default password and
assign the LX II its IP address at the Local Console.
All other steps can be performed either from the Local Console, or
the LX II Remote Console via a supported web browser using the LX
II's default IP address.
Java is required to use the Java-based VKC/VKCS client. See the
Release Notes for supported versions.
Microsoft .NET is required to use the Microsoft Windows-based
AKC client. See the Release Notes for supported versions.
Factory Default Login Information
The LX II device is shipped with the following default settings:
•
Username =
admin
•
Password =
raritan
•
IP address =
192.168.0.192
Important: For backup and business continuity purposes, it is
strongly recommended you create a backup administrator
username and password, and keep that information in a secure
location.
Change the Default Password
The first time you start the LX II device, you are required to change
the default password.
1.
Once the unit has booted, enter the default username
admin
and password
raritan
.
2.
Click Login.
3.
Enter the old password
raritan
, then enter and reenter a
new password.
Up to 64 English alphanumeric and special characters.
4.
Click Apply, then click OK on the Confirmation page.