LEGRAND pass & seymour LightSense PSWS Installation Instructions Manual Download Page 7

CLEANING

Clean using a cloth dampened only with water and a little mild detergent.
Use of solvents or hydrocarbon-based cleaners may cause permanent damage.

TROUBLESHOOTING

During Set House ID, the LED is not flashing on some

LightSense™ wireless devices.

• If LED is solid green before initiating house ID binding:

The device already has another house ID. Reset it to the factory default

so that it can be bound to the desired house ID. Resetting to factory

defaults is described in the “I need to start over” issue.

• If LED is solid yellow after initiating house ID binding:

The device may be out of range of the initiating device. Add a PSWO

LightSense Wireless Repeater to boost signal range.

I made a configuration mistake. I need to start over.

You can reset any Lightsense wireless device to factory default settings

by pressing and holding

until the LED changes to solid yellow

(approximately 10 seconds). During the process, the LED flashes yellow

and when complete, it changes to solid yellow. The device can then be

reconfigured, exactly like any new device (see the Set House ID section).

The switch does not work and the status LED is flashing red

at 2Hz (10 times in 5 seconds):

The switch has detected an overload condition and has shut down.
To clear the fault condition, tap

and wait for the LED to turn green.

Disconnect loads in excess of rated load and try again.

Summary of Contents for pass & seymour LightSense PSWS

Page 1: ...0VAC 60Hz Maximum Load Rating 800W Load Type Compatibility 0 to 800W Non dimmable fluorescent ballasts Discharge lighting fixtures Fixtures with integral dimmers AC motors and pumps U S Patent 5 804 9...

Page 2: ...agile Top Dog technology LightSense wireless devices avoid interference with other 900MHz devices such as cordless phones and baby monitors Load Types Use the PSWS for the following load types up to...

Page 3: ...al on a LightSense device both wires must be the same gauge 12AWG or 14AWG 4 Wire the LINE black LOAD NEUT white and GND green or bare supply and load wires to the correspondingly marked screw termina...

Page 4: ...n about 2 seconds All device LEDs in the House change to solid green indicating house binding is complete Adding a Device to an Existing Installation If you re adding or replacing a device in a LightS...

Page 5: ...power failure all LightSense devices automatically return to the state that they were in immediately prior to loss of power All configuration and scene control information is preserved When you see i...

Page 6: ...to step 1 and repeat 3 Return to the device used in step 1 and press to terminate Group binding All LEDs turn solid green Adding a Switch to a Group in an Existing System 1 Go to a device that is in t...

Page 7: ...ay be out of range of the initiating device Add a PSWO LightSense Wireless Repeater to boost signal range I made a configuration mistake I need to start over You can reset any Lightsense wireless devi...

Page 8: ...instructions concerning return or repair 2 return the product to Pass Seymour postage paid with your name and address and a written description of the installation or use of the Pass Seymour product...

Reviews: