LEGRAND pass & seymour LightSense PSWS Installation Instructions Manual Download Page 3

Visit our website for FAQs: www.passandseymour.com

INSTALLATION

For ease of installation, Pass & Seymour/Legrand recommends use of a deep

wall box.
1. Disconnect power to circuit by turning circuit breaker OFF before installation.
2. Remove the existing wall plate and switch, if one is present.
3. Strip existing wires

1/2"

. If two wires will be connected to the same terminal

on a LightSense™ device, both wires must be the same gauge (12AWG

or 14AWG).

4. Wire the LINE (black), LOAD, NEUT (white) and GND (green or bare) supply

and load wires to the correspondingly marked screw terminals, according to

the wiring diagram below.

5. Attach the wall plate.
6. Switch the circuit breaker back ON.

INSTALL IN COMPLIANCE WITH ALL

APPLICABLE CODES & STANDARDS.

Failure to follow these instructions may cause

personal injury or equipment damage.

LOAD

LINE

GND

NEUT

SUPPLY
WIRE

LOAD
WIRE

CAUTION

TURN THE POWER OFF AT THE CIRCUIT BREAKER BEFORE

INSTALLING THE DEVICE.

Summary of Contents for pass & seymour LightSense PSWS

Page 1: ...0VAC 60Hz Maximum Load Rating 800W Load Type Compatibility 0 to 800W Non dimmable fluorescent ballasts Discharge lighting fixtures Fixtures with integral dimmers AC motors and pumps U S Patent 5 804 9...

Page 2: ...agile Top Dog technology LightSense wireless devices avoid interference with other 900MHz devices such as cordless phones and baby monitors Load Types Use the PSWS for the following load types up to...

Page 3: ...al on a LightSense device both wires must be the same gauge 12AWG or 14AWG 4 Wire the LINE black LOAD NEUT white and GND green or bare supply and load wires to the correspondingly marked screw termina...

Page 4: ...n about 2 seconds All device LEDs in the House change to solid green indicating house binding is complete Adding a Device to an Existing Installation If you re adding or replacing a device in a LightS...

Page 5: ...power failure all LightSense devices automatically return to the state that they were in immediately prior to loss of power All configuration and scene control information is preserved When you see i...

Page 6: ...to step 1 and repeat 3 Return to the device used in step 1 and press to terminate Group binding All LEDs turn solid green Adding a Switch to a Group in an Existing System 1 Go to a device that is in t...

Page 7: ...ay be out of range of the initiating device Add a PSWO LightSense Wireless Repeater to boost signal range I made a configuration mistake I need to start over You can reset any Lightsense wireless devi...

Page 8: ...instructions concerning return or repair 2 return the product to Pass Seymour postage paid with your name and address and a written description of the installation or use of the Pass Seymour product...

Reviews: