Learning an opening position (PRESET mode)
This product lets
y
ou save a selected intermediate opening level.
One press on the button (with the shutter stopped) opens the shutter to the selected level. This Preset function does not
cover slat swivelling.
The controlled shutters ma
y
have different lengths which the individual switch 672 56 has to learn (calibration) before
saving a learnt opening level.
Calibration procedure :
1 - Press to put the roller shutter to the top.
2 - 2- Press the PRESET button for 10 secs : the shutter descends to the bottom then returns to the top.
The product has learnt the length of the shutter it controls, now it can learn an opening level.
Procedure for setting the opening level (PRESET), outside learning.
Set the selected opening level using the buttons
Save the level b
y
one press on the LEARN button
Press the PRESET control button
Press LEARN
16
Remark :
It has an infrared interface for controlling products of the installation using an "In One b
y
Legrand" infrared transmitter
(e.g. Cat. No. 882 00).
This "In One b
y
Legrand" product can be linked to radio products b
y
means of the PLC/RF modular interface
(Cat. No. 036 06).
(1)
Learning :
procedure that enables a scenario
(2)
to be defined and saved.
(2)
Scenario :
set of controls executed simultaneousl
y
on the varios receivers (actors) that have been linked to the transmitter (leader) during the
learning procedure.
To save a shutter opening level during learning, step 2 of "
Learning the scenario
" becomes :
Press LEARN
Press the PRESET
control button
Press the buttons
to set the required