background image

Warranty

Legrand warrants this product for a period of 3 years from the date of purchase. 
These goods come with guarantees that cannot be excluded under the Australian and New 
Zealand Consumer Laws. You are entitled to a replacement or a refund for a major failure and for 
compensation for any other reasonably foreseeable loss or damage. You are also entitled to have 
the goods repaired if the goods fail to be of acceptable quality and the failure does not amount to 
a major failure.
See the Warranty card enclosed with this product for further details.

LE12972AA             07/2021

 

 

Product Notes

Customer Service

For all Customer Service and Technical Support  
please call Monday to Friday during business hours.

Legrand Australia 
1300 369 777 
www.hpm.com.au

Legrand New Zealand 
0800 476 009 
www.hpm.co.nz

ABN: 31 000 102 661

Paper

1. 

This product must be installed and used as per these instructions. 

2. 

The mounting screws on this product should be tightened to a maximum torque of 0.8 Nm. Over 

tightening may damage the product.

 3.

 This product contains no serviceable parts and no attempt should be made to repair it. If the product is faulty it should be discarded. 

4.

 This product is not suitable for installation in hazardous and/or corrosive areas. 

5.

 Electrical installations periodically receive transient over-voltages. This product has been 

designed to minimise the effect of such voltages on connected equipment. It may not give full protection for extreme over-voltage transients such as those resulting from a 
close lightning strike. 

6.

 An IP rating of IP56 is generally considered suitable for fully exposed external installations and for areas subject to hose down.

 7.

 Extended 

exposure to UV rays (such as exposure to direct sunlight) may cause discolouration of this product. 

8.

 The material in this product may vary in colour from batch to batch. 

Colour matching from one batch to another cannot be guaranteed. 

9.

 This product utilises intellectual property in the form of registered designs, trademarks, and/or patents. 

Such intellectual property remains the property of Legrand in all cases. 

10. 

Legrand reserves the right to modify the specification of this product at any time.

Problems

Explanation

Possible solution

Lights are dim

This occurs with any garden light set-up and is referred to

as ”Voltage Drop”. Each light connected to the cable will

reduce in brightness in relation to the number of lights

preceding it and by the distance, it is away from the

transformer.

a. Do not exceed the rating of your transformer.

b. Limit the number of lamps on long runs of cable.

c. Use the shortest length of cable you can or divide lights evenly using two or more

    lengths of cable.

d. Use thicker cable.

Transformer

Switches off

Possible Cause - excessive current, HPM transformer are
fitted with“Self Resetting Thermal Overload Protector” which
automatically switches OFF the power supply, if an overload or
short circuit occur.

a. Reduce the number of lights you have attached to the cable so that it does not

    exceed the rating of the transformer.

b. Check globes, connectors or transformer terminals for any poor connections.

6

 

 Troubleshooting

7

 

 Accessories

Outdoor Garden Cables:

RGL8 (2-core 1.3mm², 10m length)

RGL9 (2-core 1.3mm², 20m length)

RGLHSC15 (2-core 0.5mm², 15m length)

Connectors:

CDGLCC4 (pack of 4 cable connector) 

Sensor: 

(Compatible only with 60VA -200VA transformers)

DGLS150 (150W dusk to dawn sensor)

Replacement Globe:

3.5W LED-MR16 (Up to 20W Halogen MR16)

3.5W LED-MR16 (Up to 35W Halogen MR16)

Spotlights:

GLLEDSLSS, GLLEDSLBL

 RGLVSPBL, RGL21, RGLVSBL

5

 

 Installation Example

If you have purchased a transformer with build in timer, you can add Automatic switching (PE170/10, PE170R2) 
and Dusk to Dawn Sensor (DGLS150).

4

 

 Installation 

STEP 1

Connect the cable to the transformer by stripping back a small amount of
insulation from each wire strand (approx.10mm). Be careful not to damage wires.
Twist wire strands to prevent loose wire escaping from terminal and to help
ensure a tight joint. Place stripped end into screw terminals on a transformer and
secure firmly with a screwdriver. 

Note:

 RGLTR220 transformer enables you to install two sets of cable wiring.

STEP 2

Extend cable and layout in required configuration. Position lights along cable line
at desired intervals.

STEP 3

Connect the garden light that will be positioned the furthest away from the
transformer first. Turn ON the power and test that the light is working. Turn OFF
the power and connect each of the remaining lights to the cable.

STEP 4

Before covering the cable, turn ON the power and check that all lights are 
working. If any lights are flickering or seem dull go back and check that all lamp
and cable connections are firm.

Compatible products can also be choosen from HPM webpage. 