background image

USA/International

A

6436 City West Parkway, Eden Prairie, MN 55344

P

800.582.6480 / 952.225.6000

F

877.894.6918 / 952.894.6918

Europe

A

Franklinstraat 14, 6003 DK Weert, Netherlands

P

+31 (0) 495 580 852

F

+31 (0) 495 580 845

Asia Pacific

A

Office No. 918 on 9/F, Shatin Galleria
18-24 Shan Mei Street

                               

Fotan, Shatin, Hong Kong 

P

852 2145 4099 

F

852 2145 4477

 KITXWXSM1U

Installation Instructions

8800-003348 Rev01

2022 Legrand | AV

www.legrandav.com

03/2022

Summary of Contents for CHIEF KITXWXSM1U

Page 1: ...I N S T A L L A T I O N I N S T R U C T I O N S JUPITER PANA105 XX LARGE MICRO ADJUST WALL MOUNT KITXWXSM1U ...

Page 2: ... thoroughly understand and follow all instructions can result in serious personal injury damage to equipment or voiding of factory warranty It is the installer s responsibility to make sure all parts are properly assembled and installed using the instructions provided WARNING Failure to provide adequate structural strength for this mounting system can result in serious personal injury or damage to...

Page 3: ... mm WITHOUT REVERSING UPRIGHTS 2 MAXIMUM MOUNTING PATTERN IS 76 9 1954 mm WITH REVERSING UPRIGHTS 3 FOR RECESSED APPLICATIONS MINIMUM VERTICAL LIFT FOR HOOK ENGAGEMENT IS 0 75 19 mm PIPE REINFORCEMENT COLLARS ANGLE 0 A DETAIL A SCALE 1 2 1 B DETAIL B SCALE 1 2 2 C DETAIL C SCALE 1 2 BACKWARDS ANGLE COMPENSATION SETTINGS ...

Page 4: ... Chave de bocas Chiave a punte aperte Steeksleutel Clé à fourche By Hand A mano Von Hand Com a mão A mano Met de hand À la main Hex Head Wrench Llave de cabeza hexagonal Sechskantschlüssel Chave de cabeça sextavada Chiave esagonale Zeskantsleutel Clé à tête hexagonale Pencil Mark Marcar con lápiz Stiftmarkierung Marcar com lápis Segno a matita Potloodmerkteken Marquage au crayon Drill Hole Perfora...

Page 5: ...ardware Kit J 4 5 16 x 2 1 2 K 4 UX10x60mm L 4 Slotted washer V 4 Wall cover XSM1 Mount Hardware Kit M 1 1 8 N 1 3 16 Q 4 1 4 20 x 3 4 P 2 3 8 16 x 3 4 S 2 Wall plate T 4 End cap W 1 X 1 left right Interface brackets Y 2 42 Rail spacer M6 x 12mm M6 x 20mm M6 x 25mm M8 x 20mm M8 x 30mm washer R 2 Pull knob Included in hardware box Included in hardware box MM 1 5 32 D 4 M8 x 12mm U 2 7 8 14 x 12 Z 2...

Page 6: ... 3 Locate Mounting Site WARNING IMPROPER INSTALLATION CAN LEAD TO MOUNT FALLING CAUSING SEVERE PERSONAL INJURY OR DAMAGE TO EQUIPMENT It is the installers responsibility to make certain the structure to which the mount is being attached is capable of supporting five times the combined weight of all components located on the mount not to exceed 250 lbs 113 4 kg NOTE If installing with the FCAXV1U P...

Page 7: ...t points are located on the studs See Figure 5 Figure 4 16 Drill 7 32 5 5mm pilot holes at markings for lower mounting holes See Figure 5 17 Use two 5 16 x 2 1 2 flanged lag bolts J and two 5 16 slotted washers L to attach the mount to the wall through the lower mounting holes See Figure 5 18 Slide rails to approximate center of screen location 19 Proceed to Locking Rails section Figure 5 Installi...

Page 8: ... 2 9 5mm x 88 9mm pilot holes at markings for lower mounting holes See Figure 6 13 Use two 5 16 x 2 1 2 flanged lag bolts J and two 5 16 slotted washers L to attach the mount to the wall through the lower mounting holes See Figure 6 14 Slide rails to approximate center of screen location Locking Rails Optional 1 Lock rails into place using two 1 4 20 x 3 4 set screws Q on mount upright Z and the 1...

Page 9: ...ting the location of interface brackets necessary there are several options 1 The wall brackets may be adjusted side to side at the point of attachment See Figure 10 2 The location of the left and right interface brackets W and X may be switched See Figure 10 Figure 10 3 If necessary the interface brackets may be reversed See Figure 11 a Remove display from mount b Remove interface brackets from d...

Page 10: ... viewing position and route cables between wall and rails CAUTION PINCH POINTS Keep fingers hands and cables out of pinch point areas 4 Open latch by pushing bottom of interface bracket up to OPEN position latching interface brackets to lower rail and then push up from bottom of interface bracket again until the interface bracket is in CLOSED position See Figure 14 Figure 14 Both interface bracket...

Page 11: ...reen See Figure 16 Figure 16 Adjustments Horizontal Adjustment 1 The mount wall brackets may be adjusted side to side at the point of attachment See Figure 17 Figure 17 2 The screen may be adjusted along rails side to side NOTE NEVER place both interface brackets W and X to one side of the wall mount center line See Figure 13 NOTE Do NOT allow both interface brackets W and X to be located on same ...

Page 12: ...gure 19 1 With interface brackets in CLOSED position See Figure 14 remove two fasteners holding tilt compensation in place on each interface bracket W and X See Figure 19 2 Adjust interface bracket for 1 or 2 back tilt as required See Figure 19 3 Tighten two fasteners removed in Step 1 See Figure 19 Figure 19 Locking Screen Interface Brackets Optional 1 Lock screen interface brackets onto mount ra...

Page 13: ... Figure 21 Attaching to FCAXV1U Optional 1 The KITXWXSM1U mount may be used with the UL Listed FCAXV1U Fusion pull out accessories Reference the Installation Manual included with FCAVX1U for full installation process See Figure 22 NOTE The combined component weight limit remains 250 lbs 113 4 kg when used with the FCAXV1U Pull Out Accessory Figure 22 1 P x 2 1 Padlock shackle 5 16 7 9mm maximum di...

Page 14: ...KITXWXSM1U Installation Instructions 14 ...

Page 15: ...Installation Instructions KITXWXSM1U 15 ...

Page 16: ...18 Europe A Franklinstraat 14 6003 DK Weert Netherlands P 31 0 495 580 852 F 31 0 495 580 845 Asia Pacific A Office No 918 on 9 F Shatin Galleria 18 24 Shan Mei Street Fotan Shatin Hong Kong P 852 2145 4099 F 852 2145 4477 KITXWXSM1U Installation Instructions 8800 003348 Rev01 2022 Legrand AV www legrandav com 03 2022 ...

Reviews: