This mode is indicated when display of burglar alarms and technical alarms are required, 
generated within the common sections, using a switchboard, item 346310, installed on 
the backbone or the riser of the video door entry system.

Installation rules:

•  On the common sections it is possible to connect contact interfaces, or technical alarms 

(gas/water leak), up to a total of 9 auxiliary channels; these must be connected to the 
IN clamp of interface item F422.

(

*

) Use a free address of the video handset.

3)  “Public riser” operating mode - configurator MOD = 3

Simple diagram for the display of alarms on common parts

Riser 1

Riser 2

Riser 3

Common system section

For the electric diagram see the switchboard 

technical sheet.

Burglar Alarm System

 (contact interfaces, gas/

water sensors, etc.)

MQ00280-e-EN

07/06/2014

SCS/SCS 

gateway

Summary of Contents for Bticino SCS

Page 1: ...es connected constitute at all effects two systems and as such they must be subjected to all existing sizing and installation rules Technical data Power supply via SCS BUS 27Vdc Operating power supply...

Page 2: ...l address e g if the scenario module is configured as A 0 PL 1 it will have to be placed on system no 1 see system example ThewebserverandthescenarioprogrammermustbeinstalledontheBUSlinewiththe lowest...

Page 3: ...to the cor responding control devices and actuators it will also be possible to install the Energy management central unit temperature central unit and the MH200N scenario pro grammer In this mode up...

Page 4: ...ry system Installation rules Onthecommonsectionsitispossibletoconnectcontactinterfaces ortechnicalalarms gas water leak up to a total of 9 auxiliary channels these must be connected to the IN clamp of...

Page 5: ...ys tem Installation of the Automation system actuators within the Burglar Alarm system is not allowed The interface does not use any addresses of the Automation system Thisconfigurationenableskeepingt...

Page 6: ...ely In view of the above it will no longer be necessary to indicate the system separation address in positions I3 and I4 therefore the interface will have to be configured by as signing any address fr...

Page 7: ...ems It is therefore possible to install for example in system no 2 a control configured as A 1 and PL 5 that will control actuator A 1 and PL 5 installed in system no 1 The use of the interface with t...

Page 8: ...reate a system with three interfaces for the connection of two Automation systems and one Burglar alarm system to one single riser If necessary each of these can be expanded physical expansion mode or...

Page 9: ...4 OUT IN C OUT IN I1 I2 I3 I4 2 MOD 2 OUT IN C OUT IN I1 I2 I3 I4 1 MOD F422 Example no 2 system with logic expansion Main riser A PL 55 175 1c Automation high addresses A PL 33 53 1b Automation inter...

Page 10: ...1 I2 I3 I4 1 MOD 4 OUT IN C OUT IN I1 I2 I3 I4 1 MOD F422 Example no 3 system without logic expansion A PL 55 175 1c Automation high addresses A PL 33 53 1b Automation intermediateaddresses A PL 01 31...

Reviews: