27
This setting lets you choose the type of temperature adjustment accord-
ing to the type of system.
1: Standard
default (recommended)
2: Proport. 5min
low-inertia systems (fan-coil)
3: Proport. 10min
medium-inertia systems (aluminium radiators)
4: Proport. 20min
high-inertia systems (cast iron radiators)
• Use the
ÅÇ
keys to select the option "
Adjustment
"
• Press
OK
to confi rm
The display shows the currently set selection.
• Use the
ÅÇ
keys to select the required adjustment
• Press
OK
to confi rm and to go back to the previous page or press
C
to exit the menu
a
nd to return to the previous page, hence cancelling
the change.
Select the Temperature adjustment
This setting lets you calibrate the measurement of the internal and
external probe.
• Use the
ÅÇ
keys to select the option "
Calibration
"
• Press
OK
to confi rm
If the external probe is set as a fl oor probe or used for the outside temperature,
the selection of the probe will be given.
• Use the
ÅÇ
keys to select the probe
• Press
OK
to confi rm
If the external probe is not operative, the calibration menu of the internal
probe will be displayed directly.
If the external probe is set for measuring the ambient temperature, the
calibration menu of the external probe (internal probe inoperative) will be
displayed directly.
• Use the
ÅÇ
keys to change the temperature
• Press
OK
to confi rm and to go back to the previous page or press
C
to exit the menu
a
nd to return to the previous page, hence cancelling
the change.
Calibrating the thermal probe
If you RESET the Chronothermostat, the temperature offset
determined during the Calibration will be removed.
Customizations
Summary of Contents for 6830 31
Page 2: ...Português 51 P Español 35 E English 19 GB Italiano 3 I ...
Page 67: ......