Configuration

Self-learning mode M=0

The configuration of the control can be made in two different modes
-   Physical configuration: by connecting the physical configurators to their housings
-   Virtual configuration: the control can be configured remotely, when no physical  
  configurators are available. (For the details refer to the Virtual Configuration).
  Regardless of the mode, an A/PL address must always be assigned to the  
 control.

To operate the LED programming and brightness adjustment pushbutton, only use the screwdriver 

provided.

Possible function

M configurator value

This operating mode can be used to associate one individual control to any key of the device. It is possible to create, delete or 
change each control. The display may be configured using any A/PL address already present in the system, or a unique address not 
used by other devices.

0

Programming the Keys
To associate a different control to each key, proceed as follows
1) Press and release the key on the back, the LEDs come on in succession; 
2) lightly touch the key to be programmed within 20 seconds: the LED will start 

flashing, confirming that the programming mode is active

3) set the control to associate to the key, by operating the corresponding controls 

and/or actuator. The LEDs start flashing in succession

4) it is now possible to repeat points 2 and 3 for all keys, including those that have 

already been associated, if these need changing

5) press the pushbutton to exit programming, or wait 20 seconds to exit programming 

automatically.

5739 12

5739 13

SET

A

room

PL light point
M

mode

SET LED display mode 