Connected energy meter 

 

Cat. number : 4 120 15

 

 

 

 

   

   

 

 

         

  

Sommaire 

Pages 

1. Description - Use ..................................... 1 
2. Range ......................................................... 1 
3. Overall dimensions .................................. 1 
4. Preparation - Connection ....................... 1 
5. General characteristics ........................... 4 
6. Compliance and approvals ..................... 5 
 

 

 

1. DESCRIPTION - USE 

Use: 

Allows to measure and view by smartphone with the Home + 
Control app the electrical consumption of an alternating single-
phase circuit via the associated closed coil. This connected version 
offers the functions of: 
- Energy consumption: automatically energy consumption 
information is available for the circuit to whom the Connected 
Contactor is wired to. 
- History of electricity consumption available via the HOME + 
CONTROL application 

Technology: 

. Single-phase current measurement, by field effect using a 
closed coil (delivered with the energy meter) and data 
transmission by radio frequency to the connected network 

2. RANGE 

Width: 

. 1 module. 17,7 mm wide. 

Rated primary current: 

. Ipn = 80A AC 

Power consumption: 

. 0.3W Maxi 

Rated voltage:

 

. 100V to 240V AC 

Rated frequency:

 

. 50Hz / 60Hz 

Configuration and use: 

Can be used with: 

- Legrand smartphone app 

«

 

HOME + CONTROL» 

 

 
. Available for free on Google Play or App Store 

 

 

 

 

 

3. OVERALL DIMENSIONS 

 

 

4. PREPARATION - CONNECTION 

Mounting: 

. On symmetrical rail EN / IEC 60715 or DIN 35. 

Operating position: 

. Vertical, Horizontal, Flat. 
 
 
 

 

 

 

Technical data sheet: F03108EN/02 

Updated on: 16/11/2020 

Created on: 14/01/2020 

 

 

Requires prior installation 

of a “with Netatmo” 

connected starter pack or 

a Gateway module. 

 

Summary of Contents for 4 120 15

Page 1: ...ed to History of electricity consumption available via the HOME CONTROL application Technology Single phase current measurement by field effect using a closed coil delivered with the energy meter and data transmission by radio frequency to the connected network 2 RANGE Width 1 module 17 7 mm wide Rated primary current Ipn 80A AC Power consumption 0 3W Maxi Rated voltage 100V to 240V AC Rated frequ...

Page 2: ...rcuit breaker The connection between the energy meter and the coil is made via a locking connector Recommended tools For the terminals Screwdriver flat blade 3 5 mm For clamping screwdriver flat blade 5 5 mm or less Connection Power screw terminals Terminal type cage Depth 9 mm Stripping length recommended 8 mm Screw head slotted 3 5 mm Type of screw M3 Tightening torque 0 5 Nm Conductor type Copp...

Page 3: ...onnected starter pack drawing of principle works with anykind of with Netatmo connected starter pack 4 PREPARATION CONNECTION continued 2 Beforehand the general circuit breaker must be turned OFF and only after wiring step done can be powered back ON to simultaneously power devices and allow them to be connected to the network 3 Press and hold the gateway module settings button for more than 3 sec...

Page 4: ...of the product 5 GENERAL CHARACTERISTICS Marking of the Connected Contactor Markings of the front side Connectors markings 5 GENERAL CHARACTERISTICS continued Lateral markings Characteristics of the measure coil Maxi measured primary current 80A AC Transformation ratio 1000 1 Rated short time thermal current Ith 3kA rms 1s Rated dynamic current Idyn 9kA Rated insulation level 3KV rms 50Hz 1min Cla...

Page 5: ...ure Min 5 C Max 45 C Ambient storage temperature Min 40 C Max 70 C Average weight 91g Volume when packed 0 62 dm3 6 COMPLIANCE AND APPROVALS Compliance to standards EN 61869 1 EN 61869 2 EN 61010 1 Environment respect Compliance with European Union Directives Compliance with Directive 2002 95 EC of 27 01 03 known as RoHS which provides for a restriction on the use of dangerous substances such as l...

Reviews: