Cat. No(s): 0 676 97

Technical data sheet: F03074EN/01 

Updated: 17/06/2022 

Created: 02/12/2019

1/2

Connected micromodule for roller shutters 

and orientable sun shades

128, av. du Maréchal-de-Lattre-de-Tassigny - 87045 LIMOGES Cedex

Tel.: 33 (0)5 55 06 87 87 - Fax: 33 (0)5 55 06 88 88

www.legrand.com

4. CONNECTION

Type of terminals: with screws

Terminals capacity: 1 x 2.5 mm

2

 - 2 x 1.5 mm

2

Stripping length: 8 mm

Srewdriver: 3 mm flat blade

5. OPERATION

Integrated time delay for up/down inversion = 500 ms

6. TECHNICAL CHARACTERISTICS

 6.1 Mechanical characteristics

Protection against impacts: IK 04                             

Protection against solid/bodies and liquids: IP 44

 6.2 Material characteristics

PC: Grey RAL 7035

Halogen-free
Self-extinguishing: 

850°C/30 s for insulating components holding live parts in place.

650°C/30 s for other insulating components.

 6.3 Electrical characteristics

Frequency bands: 2.4 GHz to 2.4835 GHz

Power level: < 100 mW
Standby consuption: 1,3 mA

Voltage: 100/240 V~

Current: 2 A
Roller shutter motor: 240 Vac max.   1 x 500 VA

 

100 Vac max.   1 x 270 VA

 6.4 Climate characteristics

Usage temperature: - 5°C to + 50°C

Storage temperature: - 10°C to + 70°C

1. USE

Connected micromodule for local or remote control of a roller shutters.

Can be combined with one or more wireless roller shutters controls.

Compatible with roller shutters with a mechanical or electronical stop

.

Caution: Must be connected to the neutral.
Not compatible with radio-controlled roller shutter motors.

Installs with screws in the attic or in the box of the shutter.

Self calibration function to enable roller shutters level control.

Orientable sun shades control function (to be selected in Home + Control 

App).

3. DIMENSIONS (mm)

2. RANGE

Description

Cat. No.

Connected micromodule for roller shutters and orien-

table sun shades.

Equiped with an LED indicator (configuration)

and a RESET button used to return to factory settings.

0 676 97

A

B

C

D

131

77

18.5

21.5

D

A

B

C

230V~    50Hz

µ

2A

RF

Made in Italy

IP  44

L

6

45

N

UP for test

RESET button

used to return

to factory settings

LED indicator:

useful during installation 

for configuration

Reviews: