TECHNICAL DATA
7
Gas Type
Natural Gas (G20) Cat
I
2H
Gas Connection
8mm
Number of Injectors
One
Injector size
Stereomatic 065
Control Max Operating Temperature
80
o
c
Inlet Pressure Cold
20 mbar (8” W.G.)
Heat Input (Gross)
5.5 kW
Weight
10 kg
1.
Front Coal & Fuel Bed
- All these ceramic components can be replaced at service intervals depending on
their condition. If the coals do require replacement, the consumer can do so provided that the Ceramic
Component Layout Instructions (pages 12-15) are adhered to. Only genuine Legend replacement parts should
be used.
Order Ref:
SSFC02, SSCM03,
2.
Oxygen Depletion Sensing Pilot
- In the unlikely event of a pilot failure, the pilot assembly should only be
replaced by a
GAS SAFE Registered Engineer
. The user must not carry out this work.
Order Ref:
LEG01
3.
Control Tap
- In the unlikely event of control tap failure, the assembly should only be replaced by a
GAS SAFE Registered Engineer
. The user must not carry out this work.
Order Ref:
LEG11