3.4.Connectors
Charge / Discharge connectors: to connect the positive pole (+) and negative pole (-) from the
battery to the inverter via DC isolator.
RS485: Active communication portal between battery and inverter.
USB To RS232: to get dynamic monitoring data of the battery from upper computer.
Address: Reserved Address portal for multiple parallel connections.
3.5.Wake Up button
Switch on: When battery is shut down, press the
ON/OFF
button for 3 seconds. It is activated
when the LED lights flicker from RUN light to the lowest capacity indicator.
Switch off: When battery is activated, press the
ON/OFF
button for 3 seconds. It will be shut
down when the LED lights flicker from lowest capacity indicator to RUN light.
RESET Key: Press RST key for 6 seconds, reset BMS, then clear all abnormal states; Press RST
key for 3 seconds, with shutdown and boot function;
3.6.Display function instruction
3.6.1. Reference of real figure
3.6.2.Display rendering