3.7 INSTALLING TO A PREFABRICATED CHIMNEY
When venting your Super Magnum Coal Stoker Stove using a
prefabricated chimney, be sure to contact local building code
authorities, and to follow the manufacturer’s instructions exactly. Use
only the manufacturer’s parts; do not use makeshift installation
techniques. All prefabricated chimneys must be tested to either the
U.S. or Canadian high-temperature standards, UL 103 or ULC-629.
Your manufactured chimney may contain more parts than is shown at
right. Include all required items in your installation. A chimney cap
(A) serves to keep rain and snow from entering the chimney. An
approved Class A chimney (B) is required for the Super Magnum
Stoker. Wall Bands (C) must be deployed for support per
manufacturer’s recommendations. A manufacturer’s Wall Support Kit
(D) will contain required items for supporting the chimney. Such kits
will cost less than individual items purchased separately. A Bottom
Cap (E, location marked, but actual cap not shown) allows for
cleaning. A Finishing Collar (F) provides inside wall protection. A
Wall Thimble (G) provides for required clearance between the
chimney pipe passing through a flammable wall. The Chimney
Connector (H) must be approved single wall, or a low clearance pipe,
installed with required clearances in place. A Roof Brace
(I) is required for chimneys that extend more than a certain distance,
as referenced by the manufacturer’s instructions, from the roof.
Manufactured chimneys may feature a built in “twist lock” at each
joint, but a Joint Band (J) is still normally required to secure pipe at
the joint. An approved Chimney Pipe Adapter (K) is required. A
Ceiling Support (L) will provide structural support for the chimney
and is typically part of a kit that includes items that maintain required
clearances to flammables. A Storm Collar (M), and Adjustable
Flashing (N) prevent water from entering the home by running down
the outside of the chimney. Additional items or a kit (O) provide
additional mounting support or fire protection to the roof joists or
other roof components.
-20-
Summary of Contents for Super Magnum Coal Stoker
Page 2: ......
Page 4: ...Super Magnum Coal Stoker Label top not actual size 4 ...
Page 5: ...Super Magnum Coal Stoker Label bottom not actual size 5 ...
Page 6: ... 6 ...
Page 12: ...2 4 COMPONENT LOCATIONS 12 ...
Page 14: ...2 6 DIMENSIONS 14 ...
Page 37: ...Reference Materials 37 ...
Page 45: ...Service and Maintenance Log Date of Service Performed By Description of Service 45 ...
Page 46: ...Service and Maintenance Log Date of Service Performed By Description of Service 46 ...