Important Safety Instructions for Charger:
NOTE: The battery pack is not fully charged out of the carton.
Read and understand all of the safety instructions, and then
follow the battery charging instructions that follow.
Before using the battery pack and charger, read and understand all of the safety instructions below, and observe all of
the cautionary markings on charger, battery pack, and the product using the battery pack.
• DANGER! Electrocution hazard.
120 volts are present at charger cord terminals. Do not probe with conductive objects.
Electric shock or electrocution may result.
• WARNING: Shock hazard. Do not allow any liquid to get inside charger. Electric shock may result.
• CAUTION: Burn hazard. To reduce the risk of injury, charge only Legacy 12 V battery packs that fit the charger
included with this tool. Do not attempt to charge any other battery types with this charger.
Other types of batteries
may burst causing personal injury and damage.
• CAUTION: Keep foreign objects out of the battery pack cavity on the charger.
Metallic objects in the battery pack cavity
can short the exposed charging contacts when the charger is plugged into the power supply. Always unplug the charger when
there is no battery pack in the cavity. Unplug charger before attempting to clean.
• CAUTION: Charger is intended for use indoors only. Do not expose charger to rain, snow, or frost.
Do not place
charger on any wet surfaces. Do not place charger in any location where water may drip or splash on the charger or on the
surface where the charger rests.
• Pull by plug rather than by cord to remove from power supply connection to reduce risk of damage to electric plug
and
cord.
Do not use charger or plug charger cord into power supply if cord or plug is damaged. Have damaged cord, plug,
or strain reliever replaced immediately.
Do not attempt to repair power cord or plug.
• Make sure cord is located so that it will not be stepped on, tripped over, or otherwise subjected to stress or damage.
• Do not use extension cord unless it is absolutely necessary.
Use of improper extension cord could result in risk of fire,
electric shock, or electrocution. If an extension cord must be used, make sure the extension cord is properly wired and in good
electrical condition. The extension cord must have adequate wire size (AWG or American Wire Gauge) for safety. The smaller
the gauge number of the wire, the greater the capacity of the cable. For example, a 16 gauge has more capacity than
18 gauge cord.
Minimum Recommended Wire Size for Extension cords
For Total Length of Cord: 25 ft (7.6m) to 50 ft (15.2 m) -- use 18 gauge minimum cord size.
75 ft (22.9 m) to 100 ft (30.5 m) -- use 16 gauge minimum cord size.
125 ft (38.1 m) to 150 ft (45.7 m) – use 14 gauge minimum cord size.
175 ft (53.3 m) – use 12 gauge minimum cord size.
• The charger is designed to operate on standard 120 V AC electrical power. Do not attempt to use it on any other
voltage.
• Do not place any object on top of charger or place the charger on a soft surface that might interfere with proper air
circulation around and under the charger to avoid excessive internal heat.
Place the charger in a position away from any
heat source.
• Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged in any way.
Replace
the charger or take it to an authorized service center.
Symbols
DC ……………...direct current
--- ……………….direct current symbol
V
………………..volts
Hz
………………hertz
psi……………….pounds per square inch (units of pressure)
AC ………………alternating current
UL ……………… Underwriter’s Laboratories listing on charger
+ ………………...Positive terminal on battery pack and charger
-……………….....Negative terminal on battery pack and charger
UL745-3...................UL Standard for Safety for Battery-Operated Tools
Specifications
Model: L1380L 12 V DC Battery Operated Grease Gun
Maximum Operating Pressure:
Continuous pressure: 4000 psi
Intermittent pressure: 6000 psi
Functional Description
The Legacy 12 V DC battery-powered, cordless grease gun allows convenient high-pressure greasing at grease pressures
up to 6000 psi, utilizing a motor and set of gears to develop pressure for dispensing grease as a single-action, positive displacement
pump. The gun is operated (after grease-loading) by squeezing the triggers to dispense grease either freely from the grease nozzle
(standard zerk coupler) or by engaging the grease coupler onto standard grease zerk fittings on equipment andmachinery for high-pres-
sure greasing. The gun is equipped with a pressure-relief valve to limit grease pressure to 6000 psi to reduce risk of motor overload,
tool damage, and to extend battery life. Additionally, an automatic bleeder valve bleed trapped air in the grease barrel to make priming
faster and easier. Do not exceed specifications or alter gun to perform beyond ratings. Such misuse will void warranty.
This product is listed in Intertek’s
Directory of Listed US Products
Grease Reservoir Capacity:
14.5 oz cartridge
16 oz bulk
Lubricant (grease): Up to NLGI #2
Battery Capacity: 1300 milliamp hours
Battery Quick Charge: 1 hour
Charger Input Power Source: 120 V AC