background image

Important Safety Instructions for Charger: 

 

NOTE: The battery pack is not fully charged out of the carton.

  Read and understand all of the safety instructions, and then

 

follow the battery charging instructions that follow.

 

Before using the battery pack and charger, read and understand all of the safety instructions below, and observe all of  

 

 

the cautionary markings on charger, battery pack, and the product using the battery pack.

 

•    DANGER!  Electrocution hazard.

 120 volts are present at charger cord terminals.  Do not probe with conductive objects.

 

 

Electric shock or electrocution may result.

 

•    WARNING:  Shock hazard.  Do not allow any liquid to get inside charger.  Electric shock may result. 

 

•    CAUTION:  Burn hazard.  To reduce the risk of injury, charge only Legacy 12 V battery packs that fit the charger

 

 

included with this tool.  Do not attempt to charge any other battery types with this charger.

  Other types of batteries  

 

 

 

may burst causing personal injury and damage.

 

•    CAUTION:  Keep foreign objects out of the battery pack cavity on the charger.

  Metallic objects in the battery pack cavity   

 

 

can short the exposed charging contacts when the charger is plugged into the power supply.  Always unplug the charger when   

 

 

there is no battery pack in the cavity.  Unplug charger before attempting to clean.

 

•    CAUTION:  Charger is intended for use indoors only.  Do not expose charger to rain, snow, or frost.

  Do not place

 

 

charger on any wet surfaces.  Do not place charger in any location where water may drip or splash on the charger or on the    

 

 

surface where the charger rests.

 

•    Pull by plug rather than by cord to remove from power supply connection to reduce risk of damage to electric plug    

  and 

cord.

  Do not use charger or plug charger cord into power supply if cord or plug is damaged.  Have damaged cord, plug,    

 

 

or strain reliever replaced immediately.  

Do not attempt to repair power cord or plug.

 

•    Make sure cord is located so that it will not be stepped on, tripped over, or otherwise subjected to stress or damage.

 

 

•    Do not use extension cord unless it is absolutely necessary.

  Use of improper extension cord could result in risk of fire,    

 

 

electric shock, or electrocution. If an extension cord must be used, make sure the extension cord is properly wired and in good   

 

 

electrical condition.  The extension cord must have adequate wire size (AWG or American Wire Gauge) for safety.  The smaller   

 

 

the gauge number of the wire, the greater the capacity of the cable.  For example, a 16 gauge has more capacity than  

 

 

 

18 gauge cord. 

Minimum Recommended Wire Size for Extension cords

 

 

For Total Length of Cord:  25 ft (7.6m) to 50 ft (15.2 m) -- use 18 gauge minimum cord size.

 

          

 

                          75 ft (22.9 m) to 100 ft (30.5 m) -- use 16 gauge minimum cord size.

                                                                     125 ft (38.1 m) to 150 ft (45.7 m) – use 14 gauge minimum cord size.
                                                                     175 ft (53.3 m) – use 12 gauge minimum cord size.

 

•    The charger is designed to operate on standard 120 V AC electrical power.  Do not attempt to use it on any other

   voltage. 
 

•    Do not place any object on top of charger or place the charger on a soft surface that might interfere with proper air    

 

 

circulation around and under the charger to avoid excessive internal heat.

  Place the charger in a position away from any  

 

 

heat source.

 

•    Do not operate the charger if it has received a sharp blow, been dropped, or otherwise damaged in any way.

  Replace    

 

 

the charger or take it to an authorized service center.

Symbols 

  

DC ……………...direct current

 

 

--- ……………….direct current symbol

  V 

………………..volts 

  Hz 

………………hertz

 

 

psi……………….pounds per square inch (units of pressure)

 

 

AC ………………alternating current

  

UL ……………… Underwriter’s Laboratories listing on charger

 

 

+ ………………...Positive terminal on battery pack and charger

 

 

-……………….....Negative terminal on battery pack and charger

 

 

UL745-3...................UL Standard for Safety for Battery-Operated Tools

  

Specifications

Model: L1380L 12 V DC Battery Operated Grease Gun
Maximum Operating Pressure:
 

Continuous pressure: 4000 psi

 

Intermittent pressure: 6000 psi

Functional Description

The Legacy 12 V DC battery-powered, cordless grease gun allows convenient high-pressure greasing at grease pressures  
up to 6000 psi, utilizing a motor and set of gears to develop pressure for dispensing grease as a single-action, positive displacement 
pump.  The gun is operated (after grease-loading) by squeezing the triggers to dispense grease either freely from the grease nozzle 
(standard zerk coupler) or by engaging the grease coupler onto standard grease zerk fittings on equipment andmachinery for high-pres-
sure greasing.  The gun is equipped with a pressure-relief valve to limit grease pressure to 6000 psi to reduce risk of motor overload, 
tool damage, and to extend battery life.  Additionally, an automatic bleeder valve bleed trapped air in the grease barrel to make priming 
faster and easier.  Do not exceed specifications or alter gun to perform beyond ratings.  Such misuse will void warranty.

This product is listed in Intertek’s 

Directory of Listed US Products

Grease Reservoir Capacity:
 

14.5 oz cartridge

 

16 oz bulk

Lubricant (grease): Up to NLGI #2

Battery Capacity: 1300 milliamp hours
Battery Quick Charge: 1 hour 
Charger Input Power Source: 120 V AC

Summary of Contents for Lock-n-Load L1380L

Page 1: ...eep proper footing and balance at all times Proper footing and balance enables better control of the tool in unexpected situations Use safety equipment Always wear eye protection Dust mask non skid sa...

Page 2: ...f battery liquid gets into your eyes flush them with clean water for a minimum of 15 minutes and seek immediate medical attention Medical note The battery cells are rechargeable nickel cadmium type A...

Page 3: ...ty of the cable For example a 16 gauge has more capacity than 18 gauge cord Minimum Recommended Wire Size for Extension cords For Total Length of Cord 25 ft 7 6m to 50 ft 15 2 m use 18 gauge minimum c...

Page 4: ...relief is factory preset at 6000 psi 500 psi If back pressure in the grease line exceeds the preset limit grease will then be expelled from this valve to reduce risk of motor overload and limit excess...

Page 5: ...manually operated grease transfer pump Follow filler pump instructions also Insert the gun filler nipple into the filler pump socket Operate the filler pump to fill the grease barrel When the followe...

Page 6: ...e Charge the battery for one full hour including quick charge time prior to initial use When the battery pack is fully charged the red light will go out and the green light will glow The battery pack...

Page 7: ...hose with grease coupler RP004087 12 V DC Ni Cad Battery Pack L1380 B 1 Hour Quick Charger L1380 C Optional Universal Filler Nipple for use with manual grease transfer pumps L2461 Optional grease cart...