background image

3

4

5

Ø145~150mm

For round trim plates: CW-4070 & CB-4070

For rectangular trim plates: M1-4300, M1-4301, 
X1-1998, X1-1999

95~100mm

135~140mm

R15mm

Stopper A
(marked #049000)

Stopper B
(marked #049001)

Washer C

5

Installation Procedure

Steps 3-5

Lefroy Brooks always recommends that plumbing products be installed by a licensed professional. 
Shut off main water supply before installation.

3

 

Cut a hole on the wall surface for fitting the trim kit. The hole dimension is as shown in figure 3

4

 

Throw away the protective cap only when the building construction is completed and you are  

 

 

ready to fit the trim kit.

 

REMOVE CAP ONLY, KEEP THE REST OF THE MUD GUARD AS IT IS NEEDED TO HOLD THE TRIM    

 

FIXING SCREWS.

5

 

Temperature Limiting Device:

 

Remove washer C, then take off stopper A & B.

Summary of Contents for M1-4100

Page 1: ...INSTALLATION OPERATING MAINTENANCE INSTRUCTIONS M1 4100 SINGLE HANDLE PRESSURE BALANCE ROUGH TO SUIT M1 4300 M1 4301...

Page 2: ...2 Contents Dimensions 3 Instalation Procedure 4 Parts List 7 Fault Finder 8 Safety Tips Care and Maintenance 9 Guarantee 10...

Page 3: ...0mm 1 2 14NPT 5 3 16 134mm 1 2 14NPT 1 2 14NPT 2 7 16 62mm 2 15 16 75mm 3 Dimensions in Inches Millimetres Whilst every effort is made to ensure accuracy design and dimensions are subject to change wi...

Page 4: ...Keep a distance of 7mm at least from the wall surface to the front of the plaster guard so that the trim kit CW 4070 CB 4070 can be fitted successfully 4 Steps 1 2 Installation Procedure Lefroy Brooks...

Page 5: ...products be installed by a licensed professional Shut off main water supply before installation 3 Cut a hole on the wall surface for fitting the trim kit The hole dimension is as shown in figure 3 4 T...

Page 6: ...6 Installation Procedure Steps 6 10 Lefroy Brooks always recommends that plumbing products be installed by a licensed professional Shut off main water supply before installation 6 Turn the valve stem...

Page 7: ...12 2 Adjusting ring 104105 3 Screw 075083 4 Fixing board 126055 5 Nut 009808 6 Sleeve 041061 7 PB cartridge assembly 507150 8 Check valve 507037 9 Spring 005006 10 Body 061930 11 Screw 008241 12 Washe...

Page 8: ...old is too low Inspect check valves to ensure they are fully open flush the system Remove and clean showerheads May need to replace if clogged Check for water pressure and adjust to proper pressure le...

Page 9: ...in water pressure between hot and cold supplies to the mixing valve the pressures should be equalized by a plumber in accordance with best practice and legislation Maintenance Your new bathroom fauce...

Page 10: ...them to be free of design and production faults at the time of delivery and that with correct use and care in accordance with our printed instructions they will function reliably Guarantee period The...

Page 11: ...s are protected by law and the use or reproduction outside the terms of an agreement is prohibited The right to modify designs and dimensions is reserved Christo Lefroy Brooks is a member of ACID Anti...