background image

 

 

 

6.

 

Product Usage 

Function of Action Button: 

6.1

 

  All functions of each trigger:

 

Function Of Action 

Trigger 

Description 

Power on 

In the network:

 Send Battery report and Wake up notification, the LED 

turn on within 1 second. 

Not in the network:

 Only the LED turn on within 5 second. 

Short press 

button one time 

Add the Motion Sensor into the Z-Wave network: 

1. 

Power on your Motion Sensor, and let your Z-Wave controller into 

add/inclusion mode. 

2. 

Implement the button action, the Motion Sensor will send out a node 

info security CC in command class list (Security inclusion), the LED 

will be fast blink for 60 seconds. 

3. 

If the inclusion is successful, the LED will be turn on within 2 seconds. 

If failed, LED will be turn off forever, and please repeat the steps in 

above. 

Remove Motion Sensor from a Z-Wave network: 

1. 

Power on your Motion Sensor, and let the Z-Wave primary controller 

into remove mode. 

2. 

Press the button on the Motion Sensor, the LED will be turn on for 60 

seconds. 

3. 

If Motion Sensor has been successfully removed from your Z-Wave 

network, the LED will be fast blink 2 seconds. If failed, LED will be 

turn off forever, and please repeat the steps in above. 

Short press 

button three time 

In the network: 

Send Wake up notification, and LED will fast blink when 

sending data, send over then the LED turn off. 

Not In the network:

 NOP. 

Press and hold 

more than 5 

seconds 

Reset Motion Sensor to factory default. 

 

NOTE:

   

1.  Triggering this action, in 5 seconds LED will be fast blink. The LED 

will be turn on within 2 second until hold time is equal to 5 seconds. 
Motion Sensor will send “Device_Reset_Locally” to the main 
controller and exclude from the Z-Wave network when the button is 

released, this procedure will reset the sensor to factory default. 

2. 

Please use this procedure only when the network primary controller is 

missing or otherwise inoperable. 

 

3. 

When not in the network, ignore this operation.

 

Summary of Contents for 7C-SS-VA-H0

Page 1: ...LEEDARSON Motion sensor Pet immunity_Z Wave We build your success in IoT...

Page 2: ...n be adapted to EU 868 42Mhz or US 908 42MHz If you want your Motion Sensor to be a security device that use secure encrypted message to communicate in a Z Wave network then a security enabled Z Wave...

Page 3: ...or after reset Sensor will send Device_Reset_Locally to the main controller and exclude from the Z Wave network when the Button is released this procedure will reset the Sensor to factory default Shor...

Page 4: ...unting height 6 23 ft to 7 55 ft 1 9m to 2 3m Light sensor 20 lux for day night bright dark Protocol Z Wave 908 42MHz US 868 42MHz EU 868 40MHz 868 42MHz 869 85MHz 921 42MHz AU Power source Battery po...

Page 5: ...nology Easy installation with bracket Low battery alarm Equipped with an anti tamper switch that reports any tampering 4 Installation Position and Notes 1 Installation position should be chosen at the...

Page 6: ...will shorten the distance of wireless communication 5 This device can be mounted on the wall only it cannot be installed on the ceiling 5 Product Installation Adding the device as accessories install...

Page 7: ...Z Wave primary controller into remove mode 2 Press the button on the Motion Sensor the LED will be turn on for 60 seconds 3 If Motion Sensor has been successfully removed from your Z Wave network the...

Page 8: ...rference that may cause undesired operation Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Hereby Corp...

Page 9: ...Command Class COMMAND_CLASS_NOTIFICATION 0x71 Command NOTIFICATION_REPORT 0x05 Command Class COMMAND_CLASS_BATTERY 0x80 Command BATTERY_REPORT 0x03 Command Class COMMAND_CLASS_DEVICE_RESET_LOCALLY 0x...

Page 10: ...x00 NA 0x01 Product ID 1 0x00 Product ID 2 0x26 Configuration Set Command Class Command Format 7 6 5 4 3 2 1 0 Command Class COMMAND_CLASS_CONFIGURATION Command CONFIGURATION_SET Parameter Number Defa...

Page 11: ...munity mode This feature is lens dependent and detection range may be reduced when Pet Immunity is enabled 0 Disable the pet immunity mode 1 Enable the pet immunity mode 0x01 1 7 Attention 1 If need t...

Page 12: ...rigger PIR function reported Quick Response Code QR Code The first 16 bytes of the ECDH Public Key and sometimes additional information is encoded into a QR Code graphic When referred to in this docum...

Reviews: