10
the interval time is 2 minutes.
103
(0x67)
4
0x1C20
The interval time of sending the luminance
reporting. if setting to
0
then the
luminance
reporting
is disabled
1. Valid values:
0x00-0x28DE80
2. The minimum interval time is 1 minutes. For
example, if the value is set to be more than 1 and
less than 60, the interval time is 1 minutes, if the
value is set to be more than 60 and less than 120,
the interval time is 2 minutes.
104
(0x68)
4
0x15180
The interval time of sending the battery level
reporting. if setting to
0
then the
battery level
reporting
is disabled
1. Valid values:
0x00-0x28DE80
2. The minimum interval time is 1 minutes. For
example, if the value is set to be more than 1 and
less than 60, the interval time is 1 minutes, if the
value is set to be more than 60 and less than 120,
the interval time is 2 minutes.
110
(0x6E)
1
0
Enable 111 ~ 114
temperature/humidity/luminance/ battery level
change reporting.
0 = Unable
1 = Enable
111
(0x6F)
2
0x000A
Configuration temperature change threshold.
Valid values:
1-500(unit 0.1
℃
)
112
(0x70)
1
0x05
Configuration humidity change threshold.
Valid values:
1-32(unit %)
113
(0x71)
2
0x0096
Configuration luminance change threshold.
Valid values:
1-65528(unit lx)
114
(0x72)
1
0x0A
Configuration battery level change threshold.
Valid values:
1-100(unit %)